MétaCan
Menu
← Back to cohort
Record W2782865215 · doi:10.1111/cid.12577

Evaluation of bone stimulation by different designs of microthreaded implants in enhancing osseointegration: An in vivo animal study supported by a numerical analysis

2018· article· en· W2782865215 on OpenAlexvenueno aff
Sindhu Sudhakar Kumararama, Sunil Kumar Mishra, Ramesh Chowdhary

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2018
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsOsseointegrationImplantDental implantDentistryTibiaFemurBiomedical engineeringMaterials scienceFinite element methodOrthodonticsMedicineSurgeryEngineeringStructural engineering

Abstract

fetched live from OpenAlex

BACKGROUND: An optimal shape of the thread design of the implants is required for equal distribution of stresses to the surrounding bone matrix and for stimulation and promotion of bone remodeling. PURPOSE: The study was construed with the aim of histomorphometric evaluation of bone stimulation generated by different microthread designed implants in enhancing osseointegration, and to assess the pattern of stress dissipation through a two-dimensional finite element analysis. MATERIALS AND METHODS: Computer Aided Designing of two type of microthreads, one V-shaped and the other Power-shaped microthreaded dental implants with only microthreads all along body of the implant from the neck to the apex was made and 30 implant prototypes were milled. Two-dimensional finite elemental analysis (FEA) was carried out to assess the pattern of stress distribution in the bone around these implant designs and for In vivo study 24 implant prototypes were placed in rabbits tibia and femur, out of which 12 were with V-shaped microthreads and the other 12 were with Power-shaped microthreads. Histomorphometric analysis was carried out of the sections obtained from the enbloc specimen retrieved from the sacrificed rabbits. RESULTS: FEA showed less stress around the V-shaped microthreaded implant model when compared to Power-shaped microthreaded implant model. Hitomorphometry showed statistical significance difference in new bone volume (BV) and Total BV for V-shaped microthreaded prototype implant. CONCLUSIONS: V-shaped microthreaded dental implant design can be preferred over Power-shaped microthreaded dental implant for proper stress distribution and for promoting osseointegration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.199
GPT teacher head0.515
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→