Technical Overview of Osseointegrated Transfemoral Prostheses: Orthopedic Surgery and Implant Design Centered

2018· article· en· W2784461186 on OpenAlexaff
Andrii Maryniak, Jan Andrysek

Bibliographic record

VenueJournal of Engineering and Science in Medical Diagnostics and Therapy · 2018
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsHolland Bloorview Kids Rehabilitation HospitalUniversity of Toronto
Fundersnot available
KeywordsOsseointegrationMedicineOrthopedic surgeryImplantProsthesisIntramedullary rodSurgeryDentistry

Abstract

fetched live from OpenAlex

Bone-anchored prostheses represent a promising solution to numerous medical complications associated with conventional socket-suspended prostheses. The following technical overview was constructed for engineers and orthopedic surgeons interested in osseointegrated implants for transfemoral prosthesis-residuum interfacing. Existing osseointegrated implants comprise different biomaterial compositions (i.e., titanium alloy versus cobalt-chromium-molybdenum alloy) and mechanical designs (i.e., screw-fixated versus press-fixated devices). Perioperative systems of osseointegration surgery include preoperative assessments (i.e., alongside inclusion and exclusion criteria), intraoperative procedures, and postoperative rehabilitation (i.e., static loading and dynamic gait rehabilitation). The intraoperative procedures involve transecting and reorganizing the residual musculature, embedding the implant into the femoral intramedullary cavity, and coupling the osseointegrated implant to an external prosthesis. Postoperative clinical evaluations have demonstrated significant biomechanical, psychological, and physiological improvements in patients using bone-anchored prostheses compared to conventional socket-suspended prostheses. Nevertheless, bacterial infections surrounding the skin-implant bio-interface, often resulting from Staphylococcus aureus or other coagulase-negative staphylococci, remain a relatively frequent medical complication, which can culminate in periprosthetic osteomyelitis and/or implant extraction. The technical overview concludes with discussing the recent Food and Drug Administration humanitarian use device designations, financial analyses between bone-anchored prostheses and socket-suspended prostheses, and applications of vibrotactile osseoperception for augmenting walking and balance feedback control.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.760
Threshold uncertainty score0.254

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.306
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Engineering and Science in Medical Diagnostics and TherapySame topicOrthopaedic implants and arthroplastyFrench-language works237,207