Postnatal dilatation of umbilical cord vessels and its impact on wall integrity: Prerequisite for the artificial placenta

2018· article· en· W2790293025 on OpenAlexafffund
Jenny Peng, Niels Rochow, Mohammadhossein Dabaghi, Radenka Bozanovic, J Jansen, Dragoş Predescu, Bryon DeFrance, Sau-Young Lee, Gerhard Fusch, P. Ravi Selvaganapathy, Christoph Fusch

Bibliographic record

VenueThe International Journal of Artificial Organs · 2018
Typearticle
Languageen
FieldMedicine
TopicNeonatal Respiratory Health Research
Canadian institutionsMcMaster UniversityUniversity of Ottawa
FundersHamilton Health Sciences FoundationCanada Research ChairsMcMaster University
KeywordsUmbilical veinUmbilical cordUmbilical arteryMedicinePlacentaAnatomyFetusPregnancyChemistryBiology

Abstract

fetched live from OpenAlex

INTRODUCTION: A lung assist device, which acts as an artificial placenta, can provide additional gas exchange for preterm and term newborns with respiratory failure. The concept of the lung assist device requires a large bore access via umbilical vessels to allow pumpless extracorporeal blood flow rates up to 30 mL/kg/min. After birth, constricted umbilical vessels need to be reopened for vascular access. The objective is to study the impact of umbilical vessel expansion on vessel integrity for achieving large bore access. METHODS: Umbilical cords from healthy term deliveries were cannulated and dilatated with percutaneous transluminal angioplasty catheters in 1 mm increments from 4 to 8 mm for umbilical artery and from 4 to 15 mm for umbilical vein, n = 6 per expansion diameter. Paraffin-embedded transverse sections of dilated and control samples were HE & Van Gieson stained. Effects of dilatation, shown by splitting, were measured. RESULTS: Umbilical vessel expansion led to concentric splitting, shown by areas devoid of extracellular matrix and nuclei in the tunica intima and media. No radial splitting was observed. Results suggest an expansion threshold of umbilical artery at 6 mm and umbilical vein at 7 mm, while maximal splitting was observed above this threshold (3.6 ± 0.8%, p = 0.043 for umbilical artery 7 mm and 6.3 ± 1.8%, p = 0.048 for umbilical vein 8 mm). Endothelial cell sloughing was present in all dilated samples but not in the control samples. CONCLUSION: The suggested thresholds for safe expansions are similar to in utero umbilical vessel diameters and demonstrate a proof of concept for attaining large bore access for the lung assist device.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.244
Threshold uncertainty score0.285

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.088
GPT teacher head0.446
Teacher spread0.358 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".