MétaCan
Menu
Back to cohort
Record W2792482132 · doi:10.1016/j.adro.2018.02.003

Low-cost optical scanner and 3-dimensional printing technology to create lead shielding for radiation therapy of facial skin cancer: First clinical case series

2018· article· en· W2792482132 on OpenAlexaff
Ankur Sharma, David Sasaki, Daniel W. Rickey, Ahmet Leylek, Chad Harris, KATE JOHNSON, Jorge E. Alpuche Aviles, Boyd McCurdy, Andy Egtberts, Rashmi Koul, Arbind Dubey

Bibliographic record

VenueAdvances in Radiation Oncology · 2018
Typearticle
Languageen
FieldMedicine
TopicNonmelanoma Skin Cancer Studies
Canadian institutionsUniversity of ManitobaCancerCare Manitoba
Fundersnot available
KeywordsScannerImaging phantomMedicineForeheadNuclear medicinePolygon meshComputer visionBiomedical engineeringOpticsArtificial intelligenceComputer scienceComputer graphics (images)PhysicsSurgery

Abstract

fetched live from OpenAlex

PURPOSE: Three-dimensional printing has been implemented at our institution to create customized treatment accessories, including lead shields used during radiation therapy for facial skin cancer. To effectively use 3-dimensional printing, the topography of the patient must first be acquired. We evaluated a low-cost, structured-light, 3-dimensional, optical scanner to assess the clinical viability of this technology. METHODS AND MATERIALS: For ease of use, the scanner was mounted to a simple gantry that guided its motion and maintained an optimum distance between the scanner and the object. To characterize the spatial accuracy of the scanner, we used a geometric phantom and an anthropomorphic head phantom. The geometric phantom was machined from plastic and included hemispherical and tetrahedral protrusions that were roughly the dimensions of an average forehead and nose, respectively. Polygon meshes acquired by the optical scanner were compared with meshes generated from high-resolution computed tomography images. Most optical scans contained minor artifacts. Using an algorithm that calculated the distances between the 2 meshes, we found that most of the optical scanner measurements agreed with those from the computed tomography scanner within approximately 1 mm for the geometric phantom and approximately 2 mm for the head phantom. We used this optical scanner along with 3-dimensional printer technology to create custom lead shields for 10 patients receiving orthovoltage treatments of nonmelanoma skin cancers of the face. Patient, tumor, and treatment data were documented. RESULTS: Lead shields created using this approach were accurate, fitting the contours of each patient's face. This process added to patient convenience and addressed potential claustrophobia and medical inability to lie supine. CONCLUSIONS: The scanner was found to be clinically acceptable, and we suggest that the use of an optical scanner and 3-dimensional printer technology become the new standard of care to generate lead shielding for orthovoltage radiation therapy of nonmelanoma facial skin cancer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.704
Threshold uncertainty score0.562

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.426
Teacher spread0.397 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueAdvances in Radiation OncologySame topicNonmelanoma Skin Cancer StudiesFrench-language works237,207