MétaCan
Menu
Back to cohort
Record W2793677293 · doi:10.3390/mps1010009

Method for the Routine Determination of Accurate Masses by Triple Quadrupole Mass Spectrometry

2018· article· en· W2793677293 on OpenAlexafffund
Pedro A. Segura, Killian Barry, Emmanuel Eysseric, Shawn Gallagher‐Duval, Philippe Venne, Guillaume Bélanger

Bibliographic record

VenueMethods and Protocols · 2018
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsUniversité de Sherbrooke
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMass spectrometryTriple quadrupole mass spectrometerQuadrupoleCalibrationAnalytical Chemistry (journal)ChemistryMass spectrumResolution (logic)SpectrometerHybrid mass spectrometerContext (archaeology)Selected reaction monitoringPhysicsOpticsComputer scienceTandem mass spectrometryChromatographyAtomic physicsArtificial intelligence

Abstract

fetched live from OpenAlex

A new method for the measurement of accurate masses using direct infusion in an electrospray-triple quadrupole mass spectrometer is presented and compared to the traditional method using high-resolution mass spectrometry. The proposed method uses internal calibrants and post-acquisition calibration of the mass spectrum signal using the MassWorks software to determine accurate masses. Then, based on parameters such as elemental composition, number of double bond equivalents, and type of ion (even- or odd-electron), etc., a list of potential molecular formula candidates are generated and ranked according to spectral accuracy, (i.e., similarity between the calibrated profile and theoretical isotopic patterns). Experiments using six diverse synthesis products showed that mass accuracy in the Quattro Premier triple quadrupole mass spectrometer (QqQMS) was ≤9.2 mDa and spectral accuracy was ≥90.6%. According to both mass accuracy tolerance (±10 mDa) and spectral accuracy, the correct molecular formula was ranked in the top seven compounds out of up to 32 potential candidates. When considering the context of the synthesis reaction, only one formula was possible. In summary, results showed that the measurement of spectral accuracy in a low-resolution instrument such as the triple quadrupole was strongly dependent on the signal intensity and the presence of interfering peaks in the profile mass range window. This study suggests that use of triple quadrupole mass spectrometry followed by post-acquisition calibration can be an economical and robust approach compared to the traditional method using high-resolution mass spectrometers for the measurement of accurate masses in routine applications using small organic molecules at microgram-per-litter concentrations in relatively clean matrices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.176
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.456
Teacher spread0.411 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2018
Admission routes2
Has abstractyes

Explore more