The need for an accurate indoor humidity model for building envelope performance analysis

2009· article· en· W2798143769 on OpenAlexvenueno aff
Fitsum Tariku, M.K. Kumaran, Paul Fazio

Bibliographic record

VenueNPARC · 2009
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsnot available
Fundersnot available
KeywordsEnvironmental scienceHumidityEnvelope (radar)Building envelopeComputer scienceMeteorologyTelecommunicationsGeography
DOInot available

Abstract

fetched live from OpenAlex

The performance of a building envelope component is usually assessed based on the moisture analysis of individual components (such as cladding, sheathing board and/or drywall) for their drying potentials and likelihood of occurrence of problems associated with high moisture accumulation. In the current building envelope simulation practice, the indoor and outdoor boundary conditions are predefined in the context of the local weather data. The indoor boundary conditions are usually assumed to be constant throughout the simulation period, or two sets of values for the summer and winter periods are assumed. Although the outdoor boundary condition (weather data) is independent of the hygrothermal condition of the envelope, the indoor condition is highly influenced by the building enclosure and occupants' activities. Consequently, simplistic assumptions of indoor humidity profiles, which ignore the dynamic coupling of the indoor environment and building enclosure and represented with a set of empirical values, may lead to inaccurate conclusion about the moisture performance of the building enclosure. In this paper, the effects of indoor humidity profiles that are assumed during moisture performance evaluation of exterior building envelope component are analyzed. The indoor humidity profiles, which are considered in the study, are based on measured and simulated data of a real house. Indoor humidity models including a whole building hygrothermal model are used to generate four indoor humidity profiles. The hygrothermal dynamic responses of the building envelope component with respect to the various cases of indoor humidity assumptions are simulated and analyzed. The simulation results suggest that it is important to have more accurate indoor boundary conditions data, which are based on measurement or whole building hygrothermal modelling, to satisfactorily asses the moisture performance of a building enclosure and potential occupants health problems related to mould growth.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.639
Threshold uncertainty score0.329

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.253
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueNPARCSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207