MétaCan
Menu
Back to cohort
Record W2799675021 · doi:10.1111/jvim.15136

Establishment of reference values of the caudal vena cava by fast-ultrasonography through different views in healthy dogs

2018· article· en· W2799675021 on OpenAlexafffund
Élodie Darnis, Søren Boysen, Anne‐Christine Merveille, Loïc Desquilbet, Serge Chalhoub, Kris Gommeren

Bibliographic record

VenueJournal of Veterinary Internal Medicine · 2018
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsUniversity of Calgary
FundersFaculty of Veterinary Medicine, University of CalgaryUniversité de Liège
KeywordsMedicineExpirationConcordance correlation coefficientConcordanceIntravascular volume statusAortaInferior vena cavaVena cavaUltrasonographyBody surface areaAllometryNuclear medicineRadiologyAnatomyCardiologyInternal medicineHemodynamicsRespiratory system

Abstract

fetched live from OpenAlex

Abstract Background Clinical assessment of intravascular volume status is challenging. In humans, ultrasonographic assessment of the inferior vena cava diameter, directly or as a ratio to the aortic diameter is used to estimate intravascular volume status. Objectives To ultrasonographically obtain reference values (RV) for caudal vena cava diameter (CVCD), area (CVCa) and aortic ratios using 3 views in awake healthy dogs. Animals One hundred and twenty-six healthy adult dogs from clients, students, faculty, or staff. Methods Prospective, multicenter, observational study. Two observer pairs evaluated CVCD by a longitudinal subxiphoid view (SV), a transverse 11th-13th right hepatic intercostal view (HV), and a longitudinal right paralumbar view (PV). Inter-rater agreements were estimated using concordance correlation coefficients (CCC). For body weight (BW)-dependent variables, RVs were calculated using allometric scaling for variables with a CCC ≥ 0.7. Results The CCC was ≤0.43 for the CVC/aorta ratio at the PV and ≤0.43 in both inspiration and expiration for CVC at the SV. The RVs using allometric scaling for CVCa at the HV for inspiration, expiration, and for CVCD at the PV were 6.16 × BW0.762, 7.24 × BW0.787, 2.79 × BW0.390, respectively. Conclusions and Clinical Importance The CVCD, measured at the HV and PV in healthy awake dogs of various breeds has good inter-rater agreement suggesting these sites are reliable in measuring CVCD. Established RVs for CVCD for these sites need further comparison to results obtained in hypovolemic and hypervolemic dogs to determine their usefulness to evaluate volume status in dogs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.007
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.370
Teacher spread0.313 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations60
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Veterinary Internal MedicineSame topicHemodynamic Monitoring and TherapyFrench-language works237,207