Clinical evaluation of the utility of a flexible 19-gauge EBUS-TBNA needle
Bibliographic record
Abstract
BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established modality for the assessment of mediastinal and hilar adenopathy. To overcome the sampling limitations of standard 21- and 22-gauge EBUS-TBNA needles, a new flexible 19-gauge (Flex 19G) needle was developed. METHODS: We performed a retrospective analysis of patients who underwent EBUS-TBNA sampling with the Flex 19G needle. A 22G needle was always used first for cytology, followed by a Flex 19G needle, either an early version (Oct/2014-Sep/2015) or a final version needle (May/2016-Jan/2017), for tissue sampling. The success rate of obtaining samples, specimen quantity, and safety were evaluated and compared. RESULTS: All sampling procedures in 45 patients and 82 targets were performed without complication and the overall diagnostic yield from cytology was 100%. Furthermore, 28% of Flex 19G samples were sufficient for histopathological diagnosis. Yield improved with an increased number of passes and if the target was larger. Compared to the early version evaluated in 52 targets, the final version of the Flex 19G needle evaluated in 30 targets provided significantly larger volume samples and more frequent diagnostic cores. Tissue obtained with the Flex 19G needle retained cohesiveness to a larger degree and was of higher cellularity compared to cytological samples processed as cell blocks. CONCLUSIONS: The Flex 19G is safe and provides larger volumetric and cohesive tissue samples that are appropriate for histopathological processing. The final version of the Flex 19G could be a good choice in selected cases where greater tissue acquisition is required.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".