Clinical evaluation of the utility of a flexible 19-gauge EBUS-TBNA needle

2018· article· en· W2799967039 on OpenAlexaff
Tomonari Kinoshita, Hideki Ujiie, Joerg Schwock, Kosuke Fujino, Christine M. McDonald, Chang Young Lee, Alexander Gregor, Chung Chun Tyan, Simon Houston, Kasia Czarnecka-Kujwa, Hisao Asamura, Kazuhiro Yasufuku

Bibliographic record

VenueJournal of Thoracic Disease · 2018
Typearticle
Languageen
FieldMedicine
TopicLung Cancer Diagnosis and Treatment
Canadian institutionsUniversity Health NetworkToronto General HospitalUniversity of Toronto
Fundersnot available
KeywordsMedicineFLEXSampling (signal processing)RadiologyNuclear medicineMathematics

Abstract

fetched live from OpenAlex

BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established modality for the assessment of mediastinal and hilar adenopathy. To overcome the sampling limitations of standard 21- and 22-gauge EBUS-TBNA needles, a new flexible 19-gauge (Flex 19G) needle was developed. METHODS: We performed a retrospective analysis of patients who underwent EBUS-TBNA sampling with the Flex 19G needle. A 22G needle was always used first for cytology, followed by a Flex 19G needle, either an early version (Oct/2014-Sep/2015) or a final version needle (May/2016-Jan/2017), for tissue sampling. The success rate of obtaining samples, specimen quantity, and safety were evaluated and compared. RESULTS: All sampling procedures in 45 patients and 82 targets were performed without complication and the overall diagnostic yield from cytology was 100%. Furthermore, 28% of Flex 19G samples were sufficient for histopathological diagnosis. Yield improved with an increased number of passes and if the target was larger. Compared to the early version evaluated in 52 targets, the final version of the Flex 19G needle evaluated in 30 targets provided significantly larger volume samples and more frequent diagnostic cores. Tissue obtained with the Flex 19G needle retained cohesiveness to a larger degree and was of higher cellularity compared to cytological samples processed as cell blocks. CONCLUSIONS: The Flex 19G is safe and provides larger volumetric and cohesive tissue samples that are appropriate for histopathological processing. The final version of the Flex 19G could be a good choice in selected cases where greater tissue acquisition is required.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.099
Threshold uncertainty score0.993

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.102
GPT teacher head0.486
Teacher spread0.383 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Thoracic DiseaseSame topicLung Cancer Diagnosis and TreatmentFrench-language works237,207