MétaCan
Menu
Back to cohort
Record W2800052151 · doi:10.1002/acm2.12329

Clinical implementation of <scp>AXB</scp> from <scp>AAA</scp> for breast: Plan quality and subvolume analysis

2018· article· en· W2800052151 on OpenAlexaff
Alexandra Guebert, Leigh Conroy, Sarah Weppler, Majed Alghamdi, Jessica L. Conway, Lindsay Harper, Tien Phan, Ivo A. Olivotto, Wendy Smith, Sarah Quirk

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsBreast cancerMedicineNuclear medicineEclipseCancerInternal medicinePhysics

Abstract

fetched live from OpenAlex

Abstract Purpose Two dose calculation algorithms are available in Varian Eclipse software: Anisotropic Analytical Algorithm ( AAA ) and Acuros External Beam ( AXB ). Many Varian Eclipse‐based centers have access to AXB ; however, a thorough understanding of how it will affect plan characteristics and, subsequently, clinical practice is necessary prior to implementation. We characterized the difference in breast plan quality between AXB and AAA for dissemination to clinicians during implementation. Methods Locoregional irradiation plans were created with AAA for 30 breast cancer patients with a prescription dose of 50 Gy to the breast and 45 Gy to the regional node, in 25 fractions. The internal mammary chain ( IMC CTV ) nodes were covered by 80% of the breast dose. AXB , both dose‐to‐water and dose‐to‐medium reporting, was used to recalculate plans while maintaining constant monitor units. Target coverage and organ‐at‐risk doses were compared between the two algorithms using dose–volume parameters. An analysis to assess location‐specific changes was performed by dividing the breast into nine subvolumes in the superior–inferior and left–right directions. Results There were minimal differences found between the AXB and AAA calculated plans. The median difference between AXB and AAA for breast CTV V 95% , was &lt;2.5%. For IMC CTV , the median differences V 95% , and V 80% were &lt;5% and 0%, respectively; indicating IMC CTV coverage only decreased when marginally covered. Mean superficial dose increased by a median of 3.2 Gy. In the subvolume analysis, the medial subvolumes were “hotter” when recalculated with AXB and the lateral subvolumes “cooler” with AXB ; however, all differences were within 2 Gy. Conclusion We observed minimal difference in magnitude and spatial distribution of dose when comparing the two algorithms. The largest observable differences occurred in superficial dose regions. Therefore, clinical implementation of AXB from AAA for breast radiotherapy is not expected to result in changes in clinical practice for prescribing or planning breast radiotherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.457
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.437
Teacher spread0.389 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207