Trace Gas Retrieval from AIUS:Algorithm Description and O<sub>3</sub> Retrieval Assessment
Bibliographic record
Abstract
AIUS (Atmospheric Infrared Ultraspectral Sounder) is an infrared occultation spectrometer onboard the Chinese GaoFen-5 satellite, which covers a spectral range of 2.4–13.3 μm (750–4100 cm−1) with a spectral resolution of about 0.02 cm−1. AIUS is designed to measure and study chemical processes of ozone (O3) and other trace gases in the upper troposphere and stratosphere around Antarctic. In this study, the corresponding retrieval methodology is described. The retrieval simulations based on the simulated spectra of AIUS have been carried out, with a focus on O3. The relative difference between the retrieved and the true O3 profiles is within 5% from the 15 km to 70 km and about 10% below 15 km. The corresponding averaging kernels illustrate that the overall retrieval information mainly come from the spectra, not the a priori. The retrieval experiments also demonstrate that the shape of the retrieved profiles resembles the shape of the true profile even if the shape of the a priori profile is different from that of the true profile. Further, we perform the O3 retrieval from the real ACE-FTS (Atmospheric Chemistry Experiment-Fourier Transform Spectrometer) measurements and compare the results with the official ACE-FTS Level-2 products. Overall, both profiles agree well in the stratosphere where the retrieval sensitivity is high. The relative difference between both profiles is about 15% below 70 km, which may due to the measurement errors and different forward model parameters.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.002 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.008 | 0.005 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".