MétaCan
Menu
Back to cohort
Record W2803535945 · doi:10.1002/rcm.8164

Rapid analysis of fentanyls and other novel psychoactive substances in substance use disorder patient urine using paper spray mass spectrometry

2018· article· en· W2803535945 on OpenAlexafffund
Joseph H. Kennedy, Jan Palaty, Chris G. Gill, Justin M. Wiseman

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2018
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsVancouver Island UniversityUniversity of VictoriaSimon Fraser UniversityD-Wave Systems (Canada)
FundersNatural Sciences and Engineering Research Council of CanadaVancouver Island University
KeywordsChemistryChromatographyMass spectrometryDrugs of abuseUrineCartridgeFentanylTandem mass spectrometryLiquid chromatography–mass spectrometryDrugPharmacologyMedicine

Abstract

fetched live from OpenAlex

RATIONALE: Drug overdose deaths due to fentanyls and other novel psychoactive substances (NPS) are on the rise. The higher potencies of fentanyl analogs compared with morphine require new technologies to identify and quantitate NPS. METHODS: Paper spray tandem mass spectrometry (MS/MS) and high-resolution mass spectrometry were used to identify and measure fentanyl analogs as well as common drugs of abuse in urine samples from substance use disorder clinics. Ten-microliter urine samples were deposited directly on paper spray cartridges previously loaded with internal standards, dried, and analyzed with no other sample treatment. Quantitative results were obtained using MS/MS. Individual drugs were identified using high-resolution accurate mass spectrometry, and confirmed by data-dependent MS/MS. RESULTS: of 0.99 or better for eight representative fentanyl analogs. Cartridges preloaded with internal standards demonstrated satisfactory quantitative results compared with LC/MS. Direct identification and confirmation of fentanyl analogs and other common drugs of abuse in urine using high-resolution accurate mass and MS/MS fragmentation were demonstrated at low picogram levels. CONCLUSIONS: Paper spray mass spectrometry can reliably identify and quantitate fentanyl analogs and other drugs of abuse in urine. Using paper spray cartridges as collection devices reduces exposure and transportation risks associated with biological fluids. Cartridges preloaded with labeled internal standards can be effective for targeted screening of fentanyl analogs and other drugs of abuse.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.305
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations51
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207