Surface integrity of polyethylene liners following trunnionosis of a dual modular neck total hip implant

2018· article· en· W2804330769 on OpenAlexaff
B. G. I. Spiegelberg, Brent A. Lanting, James L. Howard, Matthew G. Teeter, Douglas D.R. Naudie

Bibliographic record

VenueHip International · 2018
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsWestern University
Fundersnot available
KeywordsImplantMedicinePolyethyleneTotal hip arthroplastyScanning electron microscopeBiomedical engineeringSurgeryMaterials scienceComposite material

Abstract

fetched live from OpenAlex

BACKGROUND: There has been a trend in the evolution of total hip arthroplasty towards increased modularity; with this increase in modularity come some potentially harmful consequences. Modularity at the neck shaft junction has been linked to corrosion, adverse reaction to metal debris and pseudotumour formation. AIM: The aim of this retrieval study is to assess whether the surface integrity of the polyethylene (PE) liner is affected by metal wear debris in a single implant design series of THA revised for trunnionosis. METHODS: A retrieval analysis of thirty dual-taper modular neck hip prostheses was performed; the mean time from implantation to revision was 2.7 years (1.02-6.2). PE liners were analysed using a scanning electron microscope with an energy dispersive spectrometer to assess for metal particles embedded on the liner surface. Serum metal ion levels and inflammatory markers were also analysed. RESULTS: There were small numbers of metal particles present on the PE liners. The mean number of metal particles per liner was four and the particles varied in size from 0.5 µm to 122 µm mean 16 µm. All patients had elevated metal ion levels: cobalt 6.02 µg/l, chromium 1.22 µg/l, titanium 3.11 µg/l. The cobalt:chromium ratio was 7.55:1. Inflammatory markers were also marginally raised (ESR 17; CRP 10). CONCLUSION: These results suggest that retention of PE liners may be reasonable when performing isolated revision of the femoral component in cases of failure at the modular neck stem junction, especially when the inner diameter of the liner is already optimised for head size and stability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.193
Threshold uncertainty score0.645

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.295
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2018
Admission routes1
Has abstractyes

Explore more