MétaCan
Menu
Back to cohort
Record W2804717991 · doi:10.1002/ppul.24063

Reference equations for the interpretation of forced expiratory and plethysmographic measurements in infants

2018· article· en· W2804717991 on OpenAlexafffundabout
Zihang Lu, Rachel E. Foong, Krzysztof Kowalik, Theo J. Moraes, Aimée Dubeau, Diana L. Lefebvre, Stephanie D. Davis, Susan Balkovec, Allan B. Becker, Piush J. Mandhane, Stuart E. Turvey, Wendy Lou, Malcolm R. Sears, Félix Ratjen, Padmaja Subbarao

Bibliographic record

VenuePediatric Pulmonology · 2018
Typearticle
Languageen
FieldMedicine
TopicNeonatal Respiratory Health Research
Canadian institutionsChild and Family Research InstituteUniversity of AlbertaUniversity of ManitobaChildren's Hospital Research Institute of ManitobaBC Children's HospitalUniversity of TorontoSickKids FoundationMcMaster UniversityUniversity of British ColumbiaPublic Health Ontario
FundersCanadian Institutes of Health Research
KeywordsPlethysmographMedicineVital capacityPulmonary function testingPopulationGeneralized estimating equationLung functionCardiologyInternal medicineStatisticsLungMathematics

Abstract

fetched live from OpenAlex

Abstract Background Pulmonary function testing is commonly performed for diagnosis and clinical management of respiratory diseases. It is important to use appropriate reference equations from healthy subjects for interpretation of data from infants with lung disease. This study aimed to determine if published reference equations were similar to forced flow measures and plethysmographic infant pulmonary function testing data collected in the Canadian Healthy Infant Longitudinal Development (CHILD) Study. Methods Reference equations for five pulmonary function variables (FEV 0.5 , FVC, FEF 25‐75 , FEV 0.5 /FVC ratio and plethysmography (FRC pleth )) were developed using data from the nSpire system. New reference equations developed using healthy data from the CHILD Study were compared to previously published reference equations for forced flow and plethysmographic measures. Results The current analysis included 131 infants (on 181 test occasions) with forced flow measures and 161 infants (on 246 test occasions) with plethysmography measures, aged 3–24 months. Age and length were major determinants of both forced flow and plethysmography measures. In addition, ethnicity (Caucasian vs non‐Caucasian) was significantly associated with FEV 0.5 /FVC and FEF 25‐75 measures. We found that the published reference equations based on custom‐built equipment or commercially available systems provided poor fit to our current pulmonary function testing data, resulting in placing a large proportion of our healthy population outside the normal ranges. Conclusions Our current data support the need for population and device specific reference data for infant pulmonary function studies. By deriving new equipment‐specific reference equations for our healthy population, we provide normative data to other centers utilizing this equipment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.249
Threshold uncertainty score0.234

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.121
GPT teacher head0.400
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2018
Admission routes3
Has abstractyes

Explore more

Same venuePediatric PulmonologySame topicNeonatal Respiratory Health ResearchFrench-language works237,207