MétaCan
Menu
Back to cohort
Record W2804744330 · doi:10.1097/hjh.0000000000001806

Noninvasive validation of central and peripheral augmentation index estimated by a novel wrist-worn tonometer

2018· article· en· W2804744330 on OpenAlexaff
Luis García‐Ortiz, José I. Recio-Rodríguez, Cristina Agudo-Conde, A. Fernández, María C. Patino‐Alonso, Ángela de Cabo-Laso, Carmela Rodríguez-Martín, Jesús González‐Sánchez, Emiliano Rodríguez‐Sánchez, Manuel A. Gómez‐Marcos

Bibliographic record

VenueJournal of Hypertension · 2018
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Health and Disease Prevention
Canadian institutionsCanadian Physiotherapy Association
Fundersnot available
KeywordsMedicineWristPulse wave velocityPeripheralBlood pressureAnkleInternal medicineCardiologyPulse Wave AnalysisArterial stiffnessNuclear medicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: The validation of new blood pressure devices with easier use and more rapid data collection may facilitate the incorporation of these measures into clinical practice. We analyze the reliability and validity of Pulse Wave Analysis as reported by a novel wrist-worn device, easy and quick to use, comparing central and peripheral augmentation index (AIx) with the same measures from the SphygmoCor. Additionally, we analyzed clinical relevance through the association of the Pulse Wave Analysis, as reported by a novel wrist-worn device, with other cardiovascular parameters. METHODS: Cross-sectional study including 254 participants. Mean age was 51.9 ± 13.4 years and 53% were women. MEASUREMENTS: peripheral AIx (PAIx) and central AIx (CAIx) by the wrist-worn device and SphygmoCor (MM3); carotid-femoral (cf) pulse wave velocity (PWV) by SphygmoCor (MM3); cardioankle-vascular index (CAVI), ankle-brachial index (ABI) and brachial-ankle (ba) PWV by the Vasera device and carotid-intima media thickness (IMT) by ultrasonography. RESULTS: Intra-observer intra-class correlation coefficient (ICC) for PAIx was 0.886 (95% CI 0.803-0.934) and for CAIx 0.943 (95% CI 0.901-0.968) with Bland Altman limits of agreement -0.75 (-23.8 to 21.8) and 0.08 (-15.7 to 15.9), respectively. Inter-observer ICC for PAIx was 0.952 (95% CI 0.915-0.972) and CAIx 0.893 (95% CI 0.811-0.939) with limits of agreement -0.45 (-13.7 to 12.8) and 0.43 (-17.7 to 18.5), respectively. Comparing the wrist-worn device with SphygmoCor, the ICC was 0.849 (95% CI 0.798-0.887) for PAIx, and 0.783 (95% CI 0.711-0.838) for CAIx. In Bland-Altman, limits of agreement for PAIx 1.03 (-20.67 to 22.73), and for CAIx -2.14 (-24.79 to 20.50). PAIx and CAIx, from the wrist-worn device, correlated with age, CAVI, ABI, baPWV, cfPWV, IMT, glomerular filtration and cardiovascular risk. CONCLUSION: AIx measurements by wrist-worn device shows a good intra-observer and inter-observer reliability, inter-device noninvasive reliability and validity when compared with SphygmoCor, and clinical relevance by association with measures of vascular structure and function, end-organ damage and cardiovascular risk. TRIAL REGISTRATION: Clinicaltrials.gov NCT02623894; https://clinicaltrials.gov/ct2/show/NCT02623894.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.830
Threshold uncertainty score0.255

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.290
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of HypertensionSame topicCardiovascular Health and Disease PreventionFrench-language works237,207