MétaCan
Menu
Back to cohort
Record W2804997336 · doi:10.1136/bmjqs-2017-007715

Incidence and trends of central line associated pneumothorax using radiograph report text search versus administrative database codes

2018· article· en· W2804997336 on OpenAlexaff
Marc Reeson, Alan J. Forster, Carl van Walraven

Bibliographic record

VenueBMJ Quality & Safety · 2018
Typearticle
Languageen
FieldMedicine
TopicPleural and Pulmonary Diseases
Canadian institutionsOttawa Hospital
Fundersnot available
KeywordsMedicineIncidence (geometry)PneumothoraxChest radiographDatabaseLine (geometry)Diagnosis codeRadiographyMedical emergencyRadiologyEnvironmental healthComputer science

Abstract

fetched live from OpenAlex

BACKGROUND: Central line associated pneumothorax (CLAP) could be a good quality of care indicator because they are objectively measured, clearly undesirable and possibly avoidable. We measured the incidence and trends of CLAP using radiograph report text search with manual review and compared them with measures using routinely collected health administrative data. METHODS: For each hospitalisation to a tertiary care teaching hospital between 2002 and 2015, we searched all chest radiography reports for a central line with a sensitive computer algorithm. Screen positive reports were manually reviewed to confirm central lines. The index and subsequent chest radiography reports were screened for pneumothorax followed by manual confirmation. Diagnostic and procedural codes were used to identify CLAP in administrative data. RESULTS: In 685 044 hospitalisations, 10 819 underwent central line insertion (1.6%) with CLAP occurring 181 times (1.7%). CLAP risk did not change over time. Codes for CLAP were inaccurate (sensitivity 13.8%, positive predictive value 6.6%). However, overall code-based CLAP risk (1.8%) was almost identical to actual values possibly because patient strata with inflated CLAP risk were balanced by more common strata having underestimated CLAP risk. Code-based methods inflated central line incidence 2.2 times and erroneously concluded that CLAP risk decreased significantly over time. CONCLUSIONS: Using valid methods, CLAP incidence was similar to those in the literature but has not changed over time. Although administrative database codes for CLAP were very inaccurate, they generated CLAP risks very similar to actual values because of offsetting errors. In contrast to those from radiograph report text search with manual review, CLAP trends decreased significantly using administrative data. Hospital CLAP risk should not be measured using administrative data.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.042
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.024

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.042
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0070.008
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.178
GPT teacher head0.461
Teacher spread0.283 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueBMJ Quality & SafetySame topicPleural and Pulmonary DiseasesFrench-language works237,207