MétaCan
Menu
Back to cohort
Record W2805961086 · doi:10.1088/1741-2552/aac89b

A proportional control scheme for high density force myography

2018· article· en· W2805961086 on OpenAlexafffund
Alexander T Belyea, Kevin Englehart, Erik Scheme

Bibliographic record

VenueJournal of Neural Engineering · 2018
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsUniversity of New Brunswick
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsElectrical impedance myographyComputer scienceElectromyographyProportional controlUsabilityWristSIGNAL (programming language)Artificial intelligenceForearmPattern recognition (psychology)MathematicsSimulationPhysical medicine and rehabilitationControl systemMedicineEngineering

Abstract

fetched live from OpenAlex

Abstract Objective . Force myography (FMG) has been shown to be a potentially higher accuracy alternative to electromyography for pattern recognition based prosthetic control. Classification accuracy, however, is just one factor that affects the usability of a control system. Others, like the ability to start and stop, to coordinate dynamic movements, and to control the velocity of the device through some proportional control scheme can be of equal importance. To impart effective fine control using FMG-based pattern recognition, it is important that a method of controlling the velocity of each motion be developed. Methods . In this work force myography data were collected from 14 able bodied participants and one amputee participant as they performed a set of wrist and hand motions. The offline proportional control performance of a standard mean signal amplitude approach and a proposed regression-based alternative was compared. The impact of providing feedback during training, as well as the use of constrained or unconstrained hand and wrist contractions, were also evaluated. Results . It is shown that the commonly used mean of rectified channel amplitudes approach commonly employed with electromyography does not translate to force myography. The proposed class-based regression proportional control approach is shown significantly outperform this standard approach ( ρ < 0.001), yielding a R 2 correlation coefficients of 0.837 and 0.830 for constrained and unconstrained forearm contractions, respectively for able bodied participants. No significant difference ( ρ = 0.693) was found in R 2 performance when feedback was provided during training or not. The amputee subject achieved a classification accuracy of 83.4% ± 3.47% demonstrating the ability to distinguish contractions well with FMG. In proportional control the amputee participant achieved an R 2 of of 0.375 for regression based proportional control during unconstrained contractions. This is lower than the unconstrained case for able-bodied subjects for this particular amputee, possibly due to difficultly in visualizing contraction level modulation without feedback. This may be remedied in the use of a prosthetic limb that would provide real-time feedback in the form of device speed. Conclusion . A novel class-specific regression-based approach is proposed for multi-class control is described and shown to provide an effective means of providing FMG-based proportional control.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.752
Threshold uncertainty score0.462

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.203
Teacher spread0.196 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2018
Admission routes2
Has abstractyes

Explore more