MétaCan
Menu
Back to cohort

Prospective observational study of point-of-care ultrasound for diagnosing pneumonia

2018· article· en· W2806436306 on OpenAlexaff
Claire Lissaman, Panida Kanjanauptom, Cyril Ong, Mark O. Tessaro, Elliot Long, Adam O’Brien

Bibliographic record

VenueArchives of Disease in Childhood · 2018
Typearticle
Languageen
FieldMedicine
TopicUltrasound in Clinical Applications
Canadian institutionsHospital for Sick ChildrenUniversity of Toronto
Fundersnot available
KeywordsMedicineObservational studyPneumoniaIntensive care medicinePoint of care ultrasoundPoint-of-care testingProspective cohort studyUltrasoundPoint of carePediatricsRadiologyInternal medicinePathology

Abstract

fetched live from OpenAlex

OBJECTIVES: The clinical diagnosis of pneumonia lacks specificity and may lead to antibiotic overuse, whereas radiological diagnoses can lack sensitivity. Point-of-care lung ultrasound is an emerging diagnostic tool. There are limited prospective data, however, on the accuracy of sonologists in the paediatric emergency department setting. We aimed to test the diagnostic accuracy of lung ultrasound for pneumonia using chest radiograph (CR) as the reference standard. METHODS: This prospective observational cohort study in a paediatric emergency department enrolled children aged 1 month to <18 years, who had a CR ordered for possible pneumonia. Lung ultrasounds were performed by two blinded sonologists with focused training. Sonographic pneumonia was defined as lung consolidation with air bronchograms. Radiograph and ultrasound results both required agreement between two readers, with final results determined by an arbiter in cases of disagreement. Patient management was decided by treating clinicians who were blinded to lung ultrasound results. Follow-up was performed by phone and medical record review to obtain final diagnosis and antibiotic use. RESULTS: Of 97 included patients, CR was positive for pneumonia in 44/97 (45%) and lung ultrasound was positive in 57/97 (59%). Ultrasound sensitivity was 91% (95% CI 78% to 98%) and specificity was 68% (95% CI 54% to 80%). Ultrasound results displayed greater consistency with CR and patient outcomes when sonographic consolidation exceeded 1 cm. Thirteen of 57 patients with sonographic consolidation improved without antibiotics. CONCLUSION: Lung ultrasound may have a role as first-line imaging in patients with possible pneumonia, with higher specificity for consolidations exceeding 1 cm. TRIAL REGISTRATION NUMBER: ACTRN12616000361404, http://www.ANZCTR.org.au/ACTRN12616000361404.aspx.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.029

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.015
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.355
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations60
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueArchives of Disease in ChildhoodSame topicUltrasound in Clinical ApplicationsFrench-language works237,207