MétaCan
Menu
Back to cohort
Record W2809119426 · doi:10.1002/nbm.3944

Size‐adaptable 13‐channel receive array for brain MRI in human neonates at 3 T

2018· article· en· W2809119426 on OpenAlexafffund
Nibardo Lopez Rios, Alexandru Foias, Gregory A. Lodygensky, Mathieu Dehaes, Julien Cohen‐Adad

Bibliographic record

VenueNMR in Biomedicine · 2018
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversité de MontréalMontreal Heart InstitutePolytechnique MontréalCentre Hospitalier Universitaire Sainte-Justine
FundersFonds de recherche du Québec – Nature et technologiesFonds de Recherche du Québec - SantéNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General HospitalConcordia UniversityCanada Foundation for Innovation
KeywordsElectromagnetic coilHead (geology)Channel (broadcasting)SIGNAL (programming language)Noise (video)Cortex (anatomy)Range (aeronautics)Computer scienceMedicineBiomedical engineeringPhysicsNeuroscienceMaterials sciencePsychologyArtificial intelligenceBiologyTelecommunications

Abstract

fetched live from OpenAlex

Neonatal brain injury suffered by preterm infants and newborns with some medical conditions can cause significant neurodevelopmental disabilities. MRI is a preferred method to detect these accidents and perform in vivo evaluation of the brain. However, the commercial availability and optimality of receive coils for the neonatal brain is limited, which in many cases leads to images lacking in quality. As extensively demonstrated, receive arrays closely positioned around the scanned part provide images with high signal-to-noise ratios (SNRs). The present work proposes a pneumatic-based MRI receive array that can physically adapt to infant head dimensions from 27-week premature to 1.5 months old. Average SNR increases of up to 68% in the head region and 122% in the cortex region, compared with a 32-channel commercial head coil, were achieved at 3 T. The consistent SNR distribution obtained through the complete coil size range, specifically in the cortex, allows the acquisition of images with similar quality across a range of head dimensions, which is not possible with fixed-size coils due to the variable coil-to-head distance. The risks associated with mechanical pressure on the neonatal head are minimal and the head motion is restricted. The method could be used in coil designs for other age groups, body parts and subjects.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.725
Threshold uncertainty score0.618

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.356
Teacher spread0.331 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations35
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueNMR in BiomedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207