MétaCan
Menu
Back to cohort
Record W2809357388 · doi:10.2337/db18-13-or

First Assessment of the Performance of an Implantable CGM System through 180 Days in a Primarily Adolescent Population with Type 1 Diabetes

2018· article· en· W2809357388 on OpenAlexaboutno aff
Ronnie Aronson, R.P. Rastogi, COLLEEN MDINGI, Xiaoxiao Chen, Katherine S. Tweden

Bibliographic record

VenueDiabetes · 2018
Typearticle
Languageen
FieldMedicine
TopicDiabetes Management and Research
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineContinuous glucose monitoringIncidence (geometry)PopulationDiabetes mellitusProspective cohort studyAdverse effectSingle CenterType 1 diabetesType 2 diabetesSurgeryInternal medicineEndocrinologyMathematics

Abstract

fetched live from OpenAlex

Background: An implantable continuous glucose monitoring (CGM) system (Eversense® XL, Senseonics, Maryland U.S.A) recently received CE Mark for 180-day duration in adults. The current study is the first investigation of the performance of the Eversense XL through 180 days in a primarily adolescent population with type I diabetes (T1D). Methods: This study was a prospective, single-center, single-arm, 180-day evaluation of the effectiveness and safety of the implantable CGM system among Canadian adolescent and adult participants with T1D. Effectiveness measures included mean absolute relative difference (MARD), system agreement with Yellow Springs Instrument (YSI) glucose values, and Clarke Error Grid analysis using paired CGM and reference YSI glucose analyzer values. Adult participants were inserted with two sensors and adolescent participants were inserted with one sensor in the upper arm. CGM system accuracy studies were performed every 30 days. The safety assessment included the incidence of insertion or removal procedure-related and device-related serious adverse events (SAEs) through 180 days post-insertion. Results: Thirty-Six participants (30 adolescent/6 adult, 13 female/23 male, mean age 17±9.2 years, mean BMI 22±4 kg/m2) received the CGM system. One subject withdrew at Day 1 due to intravenous access issues. CGM system agreement with YSI glucose within 15 mg/dL or 15% of YSI glucose values (N = 7163) through 60, 120 and 180 days was 82.9% (95% CI: 78.4%-86.1%), 83.6% (95% CI: 80.4%-85.7%) and 83.4% (95% CI: 79.7%-85.5%), respectively. Overall MARD was 9.4% (95% CI: 8.6%-10.5%). Clarke Error Grid analysis showed 99% of paired values in clinically acceptable error zones A and B. No insertion/removal or device-related SAEs were reported. Conclusions: The Eversense XL CGM system is safe and accurate through 180 days of Sensor wear in a primarily adolescent population. Disclosure R. Aronson: Other Relationship; Self; Novo Nordisk Inc., Janssen Pharmaceuticals, Inc., Sanofi, AstraZeneca. Research Support; Self; Eli Lilly and Company, Becton, Dickinson and Company, Merck & Co., Inc., Senseonics, Boehringer Ingelheim Pharmaceuticals, Inc. R. Rastogi: Employee; Self; Senseonics. C. Mdingi: Employee; Self; Senseonics. X. Chen: Employee; Self; Senseonics. K. Tweden: Employee; Self; Senseonics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.019
Threshold uncertainty score0.038

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.280
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueDiabetesSame topicDiabetes Management and ResearchFrench-language works237,207