MétaCan
Menu
Back to cohort
Record W2810021483 · doi:10.1167/tvst.7.4.1

Robotic Remote Controlled Stereo Slit Lamp

2018· article· en· W2810021483 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueTranslational Vision Science & Technology · 2018
Typearticle
Languageen
FieldEngineering
TopicSoft Robotics and Applications
Canadian institutionsnot available
FundersNational Eye Institute
KeywordsComputer scienceSlit lampEthernetLaptopThe InternetInternet accessStereo cameraLocal area networkComputer visionArtificial intelligenceComputer graphics (images)Computer hardwareComputer networkOptics

Abstract

fetched live from OpenAlex

PURPOSE: Our purpose was to develop a robotic remotely operated stereo slit lamp system allowing three-dimensional stereo viewing and recording of the patient's examination via local area network, Internet, and satellite. METHODS: A commercial slit lamp was modified to accept motors and servos to permit control of all optical and mechanical components of the device. The custom graphical user interface with dual high-resolution real-time stereoscopic imaging, control/position indicators, overview video, and audio were transmitted via local area network, Internet, and satellite. Under University of Miami Institutional Review Board authorization, Internet connectivity enabled multiple examiners to simultaneously view and control the slit lamp and to collaboratively discuss diagnosis and treatment options. The remote clinicians used a tablet, laptop, or desktop computer to view and control the slit lamp. RESULTS: The network, Internet, satellite-connected system was controllable from the United States, Europe, and Canada while acquiring high-resolution, real-time video in all subjects. Control of the slit lamp through Ethernet, WiFi, and 4G exhibited total system latencies of 464 ± 58, 483 ± 64, and 870 ± 66 milliseconds when transmitting within the continent, and Ethernet control exhibited a latency of 606 ± 130 milliseconds when transmitting between continents. High- and low-magnification images of healthy volunteers were acquired by a remote clinician. CONCLUSIONS: The robotic remotely operated stereo slit lamp system allows three-dimensional stereo viewing and recording of the patient's examination via local area network, Internet, and satellite. TRANSLATIONAL RELEVANCE: The robotic remotely controlled stereo slit lamp system enables remote examination of human subjects.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.873
Threshold uncertainty score0.408

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.002
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.297
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it