MétaCan
Menu
Back to cohort
Record W2810537014 · doi:10.1177/0954411918784086

Additively manufactured implant components for imaging validation studies

2018· article· en· W2810537014 on OpenAlexafffund
Madeleine L. Van de Kleut, Xunhua Yuan, George S. Athwal, Matthew G. Teeter

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2018
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsLondon Health Sciences CentreLawson Health Research InstituteWestern University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchLawson Health Research Institute
KeywordsRepeatabilityImplantRadiographyImaging phantomMedicineOrthodonticsOrthopedic surgeryBiomedical engineeringDisplacement (psychology)Rotation (mathematics)Materials scienceSurgeryNuclear medicineMathematicsGeometry

Abstract

fetched live from OpenAlex

Radiographic imaging is the current standard for evaluating postoperative joint replacements. Prior to application, such imaging methods need to be validated to determine the lower limits of performance under ideal conditions, using either a phantom or cadaver setup. Conventionally manufactured orthopedic implants for use in such studies are not always accessible and may be cost-prohibitive to purchase. We propose the use of additively manufactured implants as a cheaper, more accessible alternative for use in radiographic imaging validation studies. Bias and repeatability were compared between conventionally manufactured and additively manufactured reverse total shoulder implant sets under a standard model-based radiostereometric analysis phantom study environment. Measurements were compared using the humeral stem or glenosphere model relative to reference bone beads, and the humeral stem relative to the glenosphere model to measure implant relative displacement. Compared to the conventionally manufactured implants, the additively manufactured implants had less bias along the internal-external rotation axis (p < 0.001), but greater bias along the abduction-adduction and flexion-extension rotation axes (p = 0.005, 0.011). Additively manufactured implants had greater repeatability along the internal-external rotation axis (p < 0.001), but worse repeatability along the medial-lateral translation axis (p = 0.001) and the abduction-adduction rotation axis (p < 0.001). Differences were on the orders of 0.01 mm and 0.5°. For the purpose of validating two-dimensional-three-dimensional radiographic imaging techniques of orthopedic implants, additively manufactured implants can be used in place of conventionally manufactured implants, assuming they are fabricated to the manufacturer's specifications. Observed differences were within the errors of the measurement technique and not clinically meaningful.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.044

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.013
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.320
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicShoulder Injury and TreatmentFrench-language works237,207