Record W2846657293 · doi:10.1177/0954411918785662

Radiostereometric analysis using clinical radiographic views: Validation with model-based radiostereometric analysis for the knee

2018· article· en· W2846657293 on OpenAlexafffund
Xunhua Yuan, Jordan S. Broberg, Douglas D.R. Naudie, David W. Holdsworth, Matthew G. Teeter

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2018
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsLawson Health Research InstituteWestern University
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaOntario Ministry of Research, Innovation and ScienceSmith and Nephew
KeywordsReproducibilityRepeatabilityRadiographyOrthodonticsStandard deviationComputer scienceMedicineMathematicsSurgery

Abstract

fetched live from OpenAlex

Radiostereometric analysis is a sophisticated radiographic technique with high measurement accuracy. In order to improve the accessibility of radiostereometric analysis for clinical use, a modified radiostereometric analysis procedure has been previously proposed that enables clinical radiographic views to be used for radiostereometric analysis. It has been successfully validated for its application to the hip wear study with the conventional bead-based radiostereometric analysis environment using computed radiography. In this study, we describe the implementation and validation of this technique for the knee study with the model-based radiostereometric analysis environment using digital radiography. A knee-joint phantom with 6 degrees of freedom was examined, and the bias and repeatability/reproducibility of the modified radiostereometric analysis approach were investigated following the newly updated ASTM recommendations. The bias parameters (mean ± 95% confidence interval) ranged from 0.008 ± 0.003 mm to 0.027 ± 0.006 mm for translation and from 0.014° ± 0.007° to 0.040° ± 0.020° for rotation. The repeatability standard deviation ranged from 0.004 to 0.020 mm for translation and from 0.005° to 0.015° for rotation. The 95% repeatability limit ranged from 0.011 to 0.055 mm for translation and from 0.014° to 0.041° for rotation. The reproducibility standard deviation ranged from 0.004 to 0.023 mm for translation and from 0.006° to 0.040° for rotation. The 95% reproducibility limit ranged from 0.012 to 0.063 mm for translation and from 0.016° to 0.112° for rotation. The modified procedure allows routine clinical radiographs to be used for radiostereometric analysis, which provides the possibility of adding quantitative measurements to current patient registries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.017
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.052

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.017
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.316
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207