MétaCan
Menu
Back to cohort
Record W2885627232 · doi:10.1093/eurheartj/ehy424

Transcatheter mitral valve repair for functional mitral regurgitation using the Cardioband system: 1 year outcomes

2018· article· en· W2885627232 on OpenAlexaff
David Messika–Zeitoun, Georg Nickenig, Azeem Latib, Karl-Heinz Kuck, Stephan Baldus, Robert Schueler, Giovanni La Canna, Eustachio Agricola, Felix Kreidel, Michael Huntgeburth, Michel Züber, Patrick Verta, Paul Grayburn, Alec Vahanian, Francesco Maisano

Bibliographic record

VenueEuropean Heart Journal · 2018
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversity of Ottawa
FundersEdwards Lifesciences
KeywordsMedicineFunctional mitral regurgitationCardiologyMitral valve repairInternal medicineMitral regurgitationMitral valveMitraClipHeart failureEjection fraction

Abstract

fetched live from OpenAlex

Aims: The Cardioband™ (Edwards Lifesciences) is a transcatheter implant designed to reduce mitral annulus size and mitral regurgitation (MR) severity. We report the 1-year outcomes of consecutive patients who underwent the Cardioband procedure between 2013 and 2016. Methods and results: Sixty patients with moderate or severe secondary MR (72 ± 7 years, 60% ischaemic origin) on guideline-recommended medical therapy were treated and analyzed at 11 European institutions. There were two in-hospital deaths (none device-related), one stroke, two coronary artery complications, and one tamponade. Anchor disengagement, observed in 10 patients (all but one in the first half of the population), resulted in device inefficacy in five patients and led to device modification half way through the study to mitigate this issue. Technical, device, and procedural successes, assessed based on Mitral Valve Academic Research Consortium (MVARC) criteria, were 97% (58/60), 72% (43/60), and 68% (41/60), respectively. At 1-year, overall survival, survival free of readmission for heart failure, and survival free of reintervention (performed in seven patients) were 87%, 66%, and 78%, respectively. In the overall population, MR grade at 12 months was moderate or less 61% and moderate or less in 95% of the 39 patients who underwent a transthoracic echocardiography at 1-year [but worsened by at least one grade in 11 patients (22%)]. Functional status (79% vs. 14% in New York Heart Association Class I/II), quality of life (-19 points on the Minnesota Living with Heart Failure Questionnaire score), and exercise capacity (+58 m by 6MWT) improved significantly (all P < 0.01). Conclusion: In this multicentre trial, the Cardioband mitral system demonstrated reasonable performance and safety. At 1 year, most patients had moderate or less MR and experienced significant functional improvements. A randomized controlled trial is underway to demonstrate the impact of Cardioband in patients on guideline-directed medical therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.022
Threshold uncertainty score0.939

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.009
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.358
Teacher spread0.292 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations165
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Heart JournalSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207