MétaCan
Menu
← Back to cohort
Record W2886452643

Dlahová osteosyntéza u periprotetických zlomenin typu Vancouver B1 a B2

2009· article· cs· W2886452643 on OpenAlexaboutno aff
Jan Fousek, P. Vašek

Bibliographic record

VenueACHOT · 2009
Typearticle
Languagecs
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsMedicinePeriprostheticOsteosynthesisRadiographySurgeryInternal fixationPerioperativeImplantRetrospective cohort studyArthroplasty
DOInot available

Abstract

fetched live from OpenAlex

PURPOSE OF THE STUDYIn a retrospective study we evaluated the results of plate osteosynthesis for treatment of periprosthetic femoral fractures classified as Vancouver types B1 and B2.MATERIAL AND METHODSThe group comprised 19 patients with post-operative periprosthetic fractures treated by open reduction and internal fixation with plate osteosynthesis at our department between the beginning of 2004 and June 2007. Perioperative fractures were not included. The average age of the patients was 72.0 (range, 53 to 88) years. A locking compression plate (PCL) was used in 16 patients. The average follow-up was 21 months, with 6 months at least. We evaluated radiographs of the fracture and, in the majority of cases, also those before a periprosthetic fracture occurred. We focussed on the signs of potential femoral component loosening and the course of fracture line; fractures were classified according to the Vancouver classification system. Follow-up included both clinical and radiographic examination.RESULTSThirteen patients showed bone union and a good functional outcome. One patient was present at follow-up only once and was not included in the final evaluation. Non-union was recorded in five patients (27.7 %), marked implant migration occurred in three (all had type B2 fracture) and osteosynthesis failed in two patients.DISCUSSIONWe consider the Vancouver classification to be the most suitable classification system. The relatively high proportion of non-union fractures can be accounted for by an inappropriate indication for osteosynthesis in fractures with stem loosening. The assessment of stem stability based on a radiograph only may, in some cases, be questionable; therefore, if doubtful, we prefer an intra-operative evaluation of implant stability. We also discuss a contribution of angle-stable plates to the osteosynthesis of periprosthetic fractures as well as their bone fixation technique.CONCLUSIONSPlate osteosynthesis is a suitable method for treatment of periprosthetic fractures if there is a stable femoral component. LPC implants are not discriminative enough in the range of indications for plate osteosynthesis. The use of plate osteosynthesis in a total hip arthroplasty with signs of loosening is bound to lead to acceleration of loosening and stem migration, and may even result in plate breakage or its expulsion. This implies that, in such THAs, plate osteosynthesis can only be carried out as a palliative procedure in immobile and severely ill old patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.260
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueACHOT→Same topicOrthopaedic implants and arthroplasty→French-language works237,207→