MétaCan
Menu
Back to cohort
Record W2896755130 · doi:10.5603/kp.2018.0208

Snuffbox to the rescue: distal transradial approach for cardiac catheterisation after failed ipsilateral radial puncture

2018· article· en· W2896755130 on OpenAlexaboutno aff
Eleftherios Kontopodis, Aggeliki Rigatou, Ioannis Tsiafoutis, Efstathios Lazaris, Michael Koutouzis

Bibliographic record

VenueKardiologia Polska · 2018
Typearticle
Languageen
FieldMedicine
TopicVascular Procedures and Complications
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineRadial arteryCardiac catheterisationCardiac catheterizationSurgeryCardiologyArtery

Abstract

fetched live from OpenAlex

We demonstrate a case of cardiac catheterisation through the left distal radial artery (dRA), in a patient with end-stage renal disease and an ipsilateral non-functioning arteriovenous (AV) fistula. An 83-year-old man with end-stage renal disease was referred for coronary angiography due to stable angina (Canadian Cardiovascular Society class III). The use of the right forearm as an access site for cardiac catheterisation was contraindicated due to the presence of a functioning AV fistula used for the haemodialysis. Moreover, transfemoral approach was not feasible because the patient had non-palpable femoral arteries and reported symptoms of intermittent claudication. We considered the left forearm approach, despite the existence of an ipsilateral non-functioning AV fistula (Fig. However, the puncture was unsuccessful, resulting in a localised haematoma and local loss of the radial pulse. The ipsilateral ulnar artery was non-palpable; therefore, no attempt of the ulnar artery puncture was carried out. The left dRA, located in the anatomical snuffbox, was chosen as an alternative access site (Fig. The puncture was successfully performed, and we introduced a 6-F, 11-cm-long hydrophilic sheath (St. Jude Medical Inc., Saint Paul, MN, USA). The arm angiogram depicted the non-functioning AV fistula (Fig. Coronary angiography (CAG) was successfully performed. An 80% stenosis of the left anterior descending artery was identified and successfully treated with a 2.75 26 mm zotarolimus eluting stent (Resolute Integrity, Medtronic Inc., Minneapolis, MN, USA). At the end of the procedure the sheath was removed, and haemostasis was achieved through manual compression. A bandage was used for 3 h (Fig. Transradial approach is regarded as the default access for coronary catheterisation and is associated with a lower rate of access-related bleeding events compared with the femoral approach [1]. The benefits of the transradial approach are even more pronounced in high-risk populations, such as in patients with end-stage renal disease Access through the dRA in the anatomical snuffbox has recently been introduced for cardiac catheterisation, and it seems to be a feasible and safe approach [3]. An algorithm promoting the use of the forearm (vs. femoral) approach during cardiac catheterisation has already been demonstrated, evaluating the possibility of using all four (two radial and two ulnar) wrist arteries In our case the left dRA was used for CAG and angioplasty after a failed puncture of the ipsilateral radial artery. The use of dRAs as access sites may increase the number of possible forearm access routes from four to six (two radial, two ulnar, and two distal radial arteries) and further reduce the use of femoral approach for cardiac catheterisation. Distal radial artery access for CAG is a new promising technique, which seems to be gaining popularity lately. As demonstrated in our case, dRA can be a safe and feasible alternative access site after the failure of the traditional forearm approach. Further randomised trials are needed in order to evaluate the possible benefits of this approach.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.665
Threshold uncertainty score0.509

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.261
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueKardiologia PolskaSame topicVascular Procedures and ComplicationsFrench-language works237,207