MétaCan
Menu
Back to cohort
Record W2900007038 · doi:10.1088/1361-6560/aaef63

Dual SPECT imaging of <sup>111</sup>In and <sup>67</sup>Ga to simultaneously determine <i>in vivo</i> the pharmacokinetics of different radiopharmaceuticals: a quantitative tool in pre-clinical research

2018· article· en· W2900007038 on OpenAlexafffund
Pedro L. Esquinas, Cristina Rodríguez‐Rodríguez, Tullio Esposito, Jeppe Harboe, Marta Bergamo, A. Ćeller, Katayoun Saatchi, Vesna Sossi, Urs O. Häfeli

Bibliographic record

VenuePhysics in Medicine and Biology · 2018
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of British Columbia
FundersNovo NordiskNatural Sciences and Engineering Research Council of CanadaLundbeckfondenNovo Nordisk FondenCanada Foundation for Innovation
KeywordsPhotonSingle-photon emission computed tomographySpect imagingNuclear medicinePhysicsIsotopeImage qualityTomographyOpticsMedical physicsComputer scienceNuclear physicsMedicineArtificial intelligenceImage (mathematics)

Abstract

fetched live from OpenAlex

Abstract Dual-isotope (DI) studies offer a number of advantages in pre-clinical imaging. These include: reducing study times when compared with sequential scans, reducing the number of animals required for any given study, and most importantly, producing images perfectly registered in space and time that provide simultaneous information about two distinct body functions. The ability of single photon emission computed tomography (SPECT) to measure and differentiate energies of the emitted photons makes it well suited for DI imaging. However, since scattered photons originating from one radioisotope may be detected in the energy window of the other and thus degrade image quality and quantitative accuracy, scatter and crosstalk corrections must be applied. The decay characteristics of 111 In and 67 Ga, which are suitable for quantitative DI imaging for up to 2 weeks post-injection, led us to investigate the performance of simultaneous 111 In/ 67 Ga SPECT imaging using a small-animal pre-clinical scanner. A series of phantom experiments were performed to investigate image quality and accuracy of activity quantification in 111 In/ 67 Ga images acquired with three different collimators and reconstructed from different photopeak combinations. The triple energy window (TEW) method was used to correct for scatter and crosstalk. Based on these phantom studies, the optimal selection of collimator and energy window settings was determined. When using these optimal settings, submillimeter-size structures were distinguishable in the reconstructed images and quantification errors below 20% were achieved for both isotopes. The optimal parameters were subsequently applied to an in vivo animal study. The determination of the distinct pharmacokinetic profiles of two polymer radiopharmaceuticals injected simultaneously, but by different administration routes (intravenously and intraperitoneally) into a single animal demonstrated the feasibility of simultaneous 111 In/ 67 Ga SPECT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.337
GPT teacher head0.547
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2018
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207