MétaCan
Menu
Back to cohort
Record W2901253186 · doi:10.1002/jmri.26518

Quantitative imaging biomarkers alliance (QIBA) recommendations for improved precision of DWI and DCE‐MRI derived biomarkers in multicenter oncology trials

2018· review· en· W2901253186 on OpenAlexaff
Amita Shukla‐Dave, Nancy A. Obuchowski, Thomas L. Chenevert, Sachin Jambawalikar, Lawrence H. Schwartz, Dariya Malyarenko, Wei Huang, Susan M. Noworolski, Robert J. Young, Mark S. Shiroishi, Harrison Kim, Catherine Coolens, Hendrik Laue, Caroline Chung, Mark Rosen, Michael A. Boss, Edward F. Jackson

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2018
Typereview
Languageen
FieldMedicine
TopicMRI in cancer diagnosis
Canadian institutionsPrincess Margaret Cancer Centre
FundersNational Center for Advancing Translational SciencesNational Center for Research ResourcesNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthNational Cancer InstituteNational Heart, Lung, and Blood InstituteSouthern California Clinical and Translational Science Institute
KeywordsMedicineMedical physicsMagnetic resonance imagingDiffusion MRIReproducibilityClinical trialImaging biomarkerRadiologyPathology

Abstract

fetched live from OpenAlex

Physiological properties of tumors can be measured both in vivo and noninvasively by diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging. Although these techniques have been used for more than two decades to study tumor diffusion, perfusion, and/or permeability, the methods and studies on how to reduce measurement error and bias in the derived imaging metrics is still lacking in the literature. This is of paramount importance because the objective is to translate these quantitative imaging biomarkers (QIBs) into clinical trials, and ultimately in clinical practice. Standardization of the image acquisition using appropriate phantoms is the first step from a technical performance standpoint. The next step is to assess whether the imaging metrics have clinical value and meet the requirements for being a QIB as defined by the Radiological Society of North America's Quantitative Imaging Biomarkers Alliance (QIBA). The goal and mission of QIBA and the National Cancer Institute Quantitative Imaging Network (QIN) initiatives are to provide technical performance standards (QIBA profiles) and QIN tools for producing reliable QIBs for use in the clinical imaging community. Some of QIBA's development of quantitative diffusion-weighted imaging and dynamic contrast-enhanced QIB profiles has been hampered by the lack of literature for repeatability and reproducibility of the derived QIBs. The available research on this topic is scant and is not in sync with improvements or upgrades in MRI technology over the years. This review focuses on the need for QIBs in oncology applications and emphasizes the importance of the assessment of their reproducibility and repeatability. Level of Evidence: 5 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;49:e101-e121.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.413
metaresearch head score (Gemma)0.402
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.413
Threshold uncertainty score0.724

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.4130.402
Meta-epidemiology (narrow)0.0030.003
Meta-epidemiology (broad)0.0050.010
Bibliometrics0.0090.007
Science and technology studies0.0020.004
Scholarly communication0.0120.008
Open science0.0130.009
Research integrity0.0120.014
Insufficient payload (model declined to judge)0.0070.009

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.113
GPT teacher head0.451
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designNot applicable
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations403
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicMRI in cancer diagnosisFrench-language works237,207