MétaCan
Menu
← Back to cohort
Record W2901621679 · doi:10.1139/cjc-2018-0298

Impact of method parameters on the performance of suspect screening for the identification of trace organic contaminants in surface waters

2018· article· en· W2901621679 on OpenAlexafffundvenue
Pedro A. Segura, Mathieu Racine, Alexia Gravel, Emmanuel Eysseric, Anne-Marie Grégoire, Diane Rawach, François-Xavier Teysseire

Bibliographic record

VenueCanadian Journal of Chemistry · 2018
Typearticle
Languageen
FieldEnvironmental Science
TopicToxic Organic Pollutants Impact
Canadian institutionsUniversité de Sherbrooke
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsCartridgeChemistryChromatographySuspectContaminationMass spectrometryExtraction (chemistry)Solid phase extractionIonizationAnalytical Chemistry (journal)Detection limitIonOrganic chemistry

Abstract

fetched live from OpenAlex

The performance of a suspect screening method to detect diverse small-molecule trace organic contaminants (TOCs) was systematically evaluated using a set of 39 model compounds. Experiments showed that ionization efficiency, ion transfer parameters, and chromatography could affect the detection of TOCs. As expected, compounds with low ionization yields and poorly retained compounds in chromatographic columns are more difficult to identify in the samples at environmental concentrations. Similarly, TOCs with large deviations from the average mass of the compounds screened were not transmitted efficiently in the mass spectrometer thus negatively affecting their detection. The suspect screening method was validated in terms of recovery and limits of identification of the model compounds using three different types of solid-phase extraction cartridges (reversed phase with polar groups, mixed-mode anion exchange, and mixed mode cation exchange). Experiments showed that more than two-thirds of the model compounds had recoveries >75% with each of the three cartridges, and comparison of limits of identification showed that more than one-half of the model compounds could be identified at concentrations between 6 and 100 ng L−1. However, it was observed that the amount of co-extracted compounds was higher in mixed-mode ion exchangers compared with the reversed-phase cartridge. Application of the suspect screening method using the three different cartridges to surface water samples showed that between 0 to 3% of the positive matches found by the peak identification algorithm were classified as probable structures. Solutions to improve suspect screening of TOCs are proposed and discussed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.021
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.044

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.021
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.265
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2018
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Journal of Chemistry→Same topicToxic Organic Pollutants Impact→French-language works237,207→