MétaCan
Menu
← Back to cohort
Record W2902609931 · doi:10.1017/s1460396918000596

Retrospective dosimetric evaluation of VMAT plans for prostate cancer treatment

2018· article· en· W2902609931 on OpenAlexaff
Johnson Darko, Ernest Osei, Andre Fleck, Ramana Rachakonda

Bibliographic record

VenueJournal of Radiotherapy in Practice · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of GuelphGrand River HospitalUniversity of Waterloo
Fundersnot available
KeywordsMedicineProstate cancerRadiation therapyProstateNuclear medicineRectumRadiation treatment planningRetrospective cohort studyBrachytherapyDosimetryCancerRadiologySurgeryInternal medicine

Abstract

fetched live from OpenAlex

Abstract Background Radiation therapy (RT) remains a common and effective treatment modality for patients with locally advanced prostate cancer. Technological advancements over the past decade have resulted in the introduction of intensity-modulated radiation therapy (IMRT) planning and delivery techniques that maximise the dose of radiation delivered to the prostate while sparing organs at risk (OAR). A more recent and evolving IMRT technique, called volumetric-modulated arc therapy (VMAT), involves a continuous irradiation at a constant or variable dose rate when the gantry rotates around the prostate using one or more arcs. Materials and methods This paper reports on a dosimetric evaluation of our implementation of VMAT technique for prostate cancer treatment. A retrospective analysis of VMAT plans was performed for 300 prostate cancer patients treated during the period of January 2013 to December 2014. Two prescription cohorts of patients treated to a dose of 78 Gy in 39 fractions as the primary radiation therapy treatment (XRT) and 66 Gy in 33 fractions as a post-op or salvage XRT were considered. Results The mean and maximal doses, dose inhomogeneities and conformity indexes for the planning target volumes were evaluated for each prescription cohort of patients. Similarly, the doses to OAR such as rectum, bladder and femoral heads were also assessed for various dose levels. Conclusion This study shows that highly conformal radiation dose distribution for the treatment of prostate cancer is achievable with the VMAT technique. It provides evidence to support the adoption of such conformal technology in many disease sites such as the prostate. We believe that our experience reported here could help form the foundation for individual institutions to evaluate and develop the most suitable planning criteria tailored to their own needs and priority. This endeavour hopefully will provide further improvement in the planning process and, therefore, help achieve an effective and efficient delivery of radiotherapy for prostate cancer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.009
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.395
Teacher spread0.372 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Radiotherapy in Practice→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→