MétaCan
Menu
Back to cohort
Record W2904080749 · doi:10.4103/jmp.jmp_52_18

Dosimetric characterization of an intensity-modulated X-ray brachytherapy system

2018· article· en· W2904080749 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Medical Physics · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Windsor
Fundersnot available
KeywordsBrachytherapyCharacterization (materials science)X-rayNuclear medicineIntensity (physics)Materials scienceMedical physicsMedicineOpticsRadiologyPhysicsRadiation therapy

Abstract

fetched live from OpenAlex

PURPOSE: An intensity-modulated X-ray brachytherapy system is being developed for various clinical applications. This new system makes it possible for clinical staff to control energy as well as dose rate for different tumor sites according to their sizes and radiobiological characteristics. MATERIALS AND METHODS: This system is mainly composed of an X-ray tube, guide tube collimation, and secondary (pseudo) target. Due to its configuration, convenient modulations of fluorescent X-ray energy and intensity are possible. To observe applicability of this novel system for various primary and secondary target combinations, Monte Carlo simulation using MCNP5 was performed, and air measurements were done. As a primary and pseudo-target combination, silver-molybdenum (Ag-Mo), tungsten-neodymium (W-Nd), and tungsten-erbium (W-Er) were used for the calculation for dose profile. Specifically, a dose distribution was calculated around each of these target combinations. Dose distributions as a function of target angles were also calculated. The Ag-Mo combination was analyzed for Cartesian coordinates of xy, xz, and yz planes of the pseudo-target to observe dose distribution as a function of the angle of secondary target. RESULTS: I) due to its low characteristic X-ray energy. CONCLUSIONS: Dose distribution variance should be considered in beam modulation for clinical application. Dynamic movement of the pseudo-target is feasible and remains as a subject for future research.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.562
Threshold uncertainty score0.374

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.287
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it