MétaCan
Menu
Back to cohort
Record W2904533125 · doi:10.2967/jnumed.118.219998

Use of a Qualification Phantom for PET Brain Imaging in a Multicenter Consortium: A Collaboration Between the Pediatric Brain Tumor Consortium and the SNMMI Clinical Trials Network

2018· article· en· W2904533125 on OpenAlexaff
Frederic H. Fahey, Paul E. Christian, Katherine Zukotynski, Briana Sexton‐Stallone, Christina Kiss, Bonnie Clarke, Arzu Onar‐Thomas, Tina Young Poussaint

Bibliographic record

VenueJournal of Nuclear Medicine · 2018
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsMcMaster University
FundersChildren's Hospital Los AngelesSt. Jude Children's Research HospitalTexas Children's HospitalMemorial Sloan-Kettering Cancer CenterChildren's Hospital of PittsburghNIH Clinical CenterNational Cancer InstituteNational Institutes of HealthCincinnati Children's Hospital Medical Center
KeywordsImaging phantomNuclear medicineWhite matterPartial volumeMedicineNeuroimagingImage qualityMedical physicsBiomedical engineeringRadiologyMagnetic resonance imagingComputer scienceArtificial intelligence

Abstract

fetched live from OpenAlex

The purpose of this study was to assess image quality and quantitative brain PET across a multicenter consortium. <b>Methods:</b> All academic centers and children’s hospitals in the Pediatric Brain Tumor Consortium (PBTC) scanned a phantom developed by the Society of Nuclear Medicine and Molecular Imaging Clinical Trials Network (SNMMI CTN) for the validation of brain PET studies associated with clinical trials. The phantom comprises 2 separate, fillable sections: a resolution/uniformity section and a clinical simulation section. The resolution/uniformity section is a cylinder 12.7 cm long and 20 cm in diameter; spatial resolution is evaluated subjectively with 2 sets of rods (hot and cold) of varying diameter (4.0, 5.0, 6.25, 7.81, 9.67, and 12.2 mm) and spacing (twice the rod diameter). The clinical simulation section simulates a transverse section of midbrain with ventricles and gray and white matter compartments. If properly filled, hot rods have a 4:1 target-to-background ratio, and gray–to–white matter sections have a 4:1 ratio. Uniformity and image quality were evaluated using the SUV in a small volume of interest as well as subjectively by 2 independent observers using a 4-point scale. <b>Results:</b> Eleven PBTC sites scanned the phantom on 13 PET scanners. The phantom’s complexity led to suboptimal filling, particularly of the hot rod section, in 5 sites. The SUV in the uniformity section was within 10% of unity on only 5 of 13 scanners, although 12 of 13 were subjectively judged to have very good to excellent uniformity. Four of 6 hot rods were discernable by all 13 scanners, whereas 3 of 6 cold rods were discernable by only 5 scanners. Four of 13 scanners had a gray–to–white matter ratio between 3.0 and 5.0 (4.0 is truth); however, 11 of 13 scanners were subjectively judged to have very good or excellent image quality. <b>Conclusion:</b> Eleven sites were able to image a powerful phantom developed by the SNMMI CTN that evaluated image uniformity, spatial resolution, and image quality of brain PET. There was considerable variation in PET data across the PBTC sites, possibly resulting from variations in scanning across the sites due to challenges in filling the phantom.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.019
metaresearch head score (Gemma)0.026
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.396
Threshold uncertainty score0.982

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0190.026
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.137
GPT teacher head0.460
Teacher spread0.323 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Nuclear MedicineSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207