MétaCan
Menu
← Back to cohort
Record W2905231271 · doi:10.2196/11896

Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis

2018· article· en· W2905231271 on OpenAlexvenueno aff
Jia Zhang, Laura Tüshaus, Néstor Nuño Martínez, Monica Moreo, Héctor Verástegui, Stella M. Hartinger, Daniel Mäusezahl, Walter Karlen

Bibliographic record

VenueJMIR mhealth and uhealth · 2018
Typearticle
Languageen
FieldHealth Professions
TopicMobile Health and mHealth Applications
Canadian institutionsnot available
FundersUBS Optimus FoundationSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungNational Science Foundation
KeywordsChecklistComputer scienceData integrityQualitative researchRisk analysis (engineering)Data scienceProcess managementPsychologyMedicineEngineeringComputer security

Abstract

fetched live from OpenAlex

BACKGROUND: Mobile health (mHealth) technologies have the potential to bring health care closer to people with otherwise limited access to adequate health care. However, physiological monitoring using mobile medical sensors is not yet widely used as adding biomedical sensors to mHealth projects inherently introduces new challenges. Thus far, no methodology exists to systematically evaluate these implementation challenges and identify the related risks. OBJECTIVE: This study aimed to facilitate the implementation of mHealth initiatives with mobile physiological sensing in constrained health systems by developing a methodology to systematically evaluate potential challenges and implementation risks. METHODS: We performed a quantitative analysis of physiological data obtained from a randomized household intervention trial that implemented sensor-based mHealth tools (pulse oximetry combined with a respiratory rate assessment app) to monitor health outcomes of 317 children (aged 6-36 months) that were visited weekly by 1 of 9 field workers in a rural Peruvian setting. The analysis focused on data integrity such as data completeness and signal quality. In addition, we performed a qualitative analysis of pretrial usability and semistructured posttrial interviews with a subset of app users (7 field workers and 7 health care center staff members) focusing on data integrity and reasons for loss thereof. Common themes were identified using a content analysis approach. Risk factors of each theme were detailed and then generalized and expanded into a checklist by reviewing 8 mHealth projects from the literature. An expert panel evaluated the checklist during 2 iterations until agreement between the 5 experts was achieved. RESULTS: Pulse oximetry signals were recorded in 78.36% (12,098/15,439) of subject visits where tablets were used. Signal quality decreased for 1 and increased for 7 field workers over time (1 excluded). Usability issues were addressed and the workflow was improved. Users considered the app easy and logical to use. In the qualitative analysis, we constructed a thematic map with the causes of low data integrity. We sorted them into 5 main challenge categories: environment, technology, user skills, user motivation, and subject engagement. The obtained categories were translated into detailed risk factors and presented in the form of an actionable checklist to evaluate possible implementation risks. By visually inspecting the checklist, open issues and sources for potential risks can be easily identified. CONCLUSIONS: We developed a data integrity-based methodology to assess the potential challenges and risks of sensor-based mHealth projects. Aiming at improving data integrity, implementers can focus on the evaluation of environment, technology, user skills, user motivation, and subject engagement challenges. We provide a checklist to assist mHealth implementers with a structured evaluation protocol when planning and preparing projects.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.311
metaresearch head score (Gemma)0.335
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.311
Threshold uncertainty score0.850

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.3110.335
Meta-epidemiology (narrow)0.0030.002
Meta-epidemiology (broad)0.0020.003
Bibliometrics0.0160.012
Science and technology studies0.0070.010
Scholarly communication0.0050.005
Open science0.0060.008
Research integrity0.0030.005
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.751
GPT teacher head0.707
Teacher spread0.044 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2018
Admission routes1
Has abstractyes

Explore more