MétaCan
Menu
Back to cohort
Record W2910909070 · doi:10.1039/c8lc01121d

Organic-free, versatile sessile droplet microfluidic device for chemical separation using an aqueous two-phase system

2019· article· en· W2910909070 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueLab on a Chip · 2019
Typearticle
Languageen
FieldEngineering
TopicElectrowetting and Microfluidic Technologies
Canadian institutionsRoyal Military College of CanadaQueen's University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsAqueous solutionMicrofluidicsExtraction (chemistry)Polyethylene glycolAnalyteChromatographyPEG ratioAqueous two-phase systemChemistryLiquid–liquid extractionSubstrate (aquarium)Analytical Chemistry (journal)Materials scienceNanotechnologyOrganic chemistry

Abstract

fetched live from OpenAlex

This work presents a novel portable, versatile sessile droplet microfluidic (SDMF) device to perform liquid manipulation operations such as confining, splitting and colorimetric detection. Furthermore, chemical isolations based on an aqueous two-phase system (ATPS) for separating an analyte of choice from a complicated sample matrix can be carried out. ATPS extractions can replace conventional liquid-liquid extractions and take away the need for harmful organic solvents. Superhydrophobic (SH) surfaces were fabricated from a commercially available material, Ultra-Ever Dry® (UED®). On these SH surfaces, surface energy traps (SETs) were produced either by air plasma treatment (simultaneously) or laser micromachining (sequentially) to dock/pin an ATPS containing droplet onto the surface. Splitting of droplets or removing a precise volume of the top phase from a pinned extraction system was achieved with a sandwich-chip approach. For this, an additional SET patterned substrate was placed on top of the droplet and subsequently lifted. This multipurpose platform was used to isolate Cd from a mixture of several other metal ions (i.e. Mn, Ni, Cu, Pb, Fe) for its subsequent interference-free detection. An ATPS consisting of sodium sulfate and polyethylene glycol (PEG) as phase forming components and potassium iodine as extractant allowed separation of cadmium with an extraction efficiency of q(Cd2+) = 98.5%. Using a portable, cost-effective, smartphone-based UV/vis spectrometer, Cd was detected with a LoD of 3.4 ppm. Alternatively, the multipurpose platform can also be used as sampling platform for a benchtop UV/vis spectrometer, where a LoD of 0.53 ppm was obtained. Potential applications of the presented platform include sample preparation and separation that can be achieved by aqueous two-phase extractions, such as proteins, antibodies, DNA, cells, organic molecules and metal ions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score0.890

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.271
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it