MétaCan
Menu
Back to cohort
Record W2912865218 · doi:10.1097/pec.0000000000001664

A Cost Analysis of Pulse Oximetry as a Determinant in the Decision to Admit Infants With Mild to Moderate Bronchiolitis

2018· article· en· W2912865218 on OpenAlexaff
Andrew Mendlowitz, Elysa Widjaja, Cathy Phan, Zhuolu Sun, Myla E. Moretti, Suzanne Schuh, Peter C. Coyte, Rebecca Hancock, Stephen B. Freedman, Wendy J. Ungar

Bibliographic record

VenuePediatric Emergency Care · 2018
Typearticle
Languageen
FieldMedicine
TopicRespiratory viral infections research
Canadian institutionsInstitute for Clinical Evaluative SciencesAlberta Children's HospitalUniversity of CalgaryHospital for Sick ChildrenUniversity of Toronto
Fundersnot available
KeywordsPulse oximetryMedicineConfidence intervalRandomized controlled trialBronchiolitisHealth careIntensive careIntensive care medicineEmergency medicinePediatricsAnesthesiaSurgeryInternal medicineRespiratory system

Abstract

fetched live from OpenAlex

OBJECTIVES: A previous randomized controlled trial showed that artificially elevating the pulse oximetry display resulted in fewer hospitalizations with no worse outcomes. This suggests that management decisions based mainly on pulse oximetry may unnecessarily increase health care costs. This study assessed the incremental cost of altered relative to true oximetry in infants with mild to moderate bronchiolitis. METHODS: A cost analysis was undertaken from the health care system and societal perspectives using patient-level data from the randomized controlled trial, with a 5-day time horizon after emergency department visit. Infants aged 4 weeks to 12 months with mild to moderate bronchiolitis were randomized to pulse oximetry measurements with true or altered saturation values displayed by artificially increasing saturation 3% points above true values. Direct and indirect health care costs were measured. Sensitivity analyses were performed to assess parameter uncertainty. RESULTS: From the health care system perspective, the average cost per patient was Can $1155 for altered oximetry and $1967 for true oximetry, with a net savings of $812. From a societal perspective, the average cost per patient was $1559 for altered oximetry and $2473 for true oximetry, with a net savings of $914. Probabilistic analyses demonstrated that altered oximetry remained the less costly study group, with an average savings of $810 (95% confidence interval, $748-$872) from the health care system perspective and $910 (95% confidence interval, $848-$973) from the societal system perspective. CONCLUSIONS: Reliance on oximetry as a major determinant in the decision to hospitalize infants with mild to moderate bronchiolitis is associated with significantly greater costs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.032
Threshold uncertainty score0.800

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.008
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.043
GPT teacher head0.402
Teacher spread0.359 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2018
Admission routes1
Has abstractyes

Explore more

Same venuePediatric Emergency CareSame topicRespiratory viral infections researchFrench-language works237,207