MétaCan
Menu
Back to cohort
Record W2912894259 · doi:10.1249/mss.0000000000001898

Novel Noninvasive Assessment of Microvascular Structure and Function in Humans

2019· article· en· W2912894259 on OpenAlexaff
Kurt J. Smith, Raden Argarini, Howard H. Carter, Bryden C. Quirk, Andrew Haynes, Louise H. Naylor, Hamish McKirdy, Rodney W. Kirk, Robert A. McLaughlin, Daniel J. Green

Bibliographic record

VenueMedicine & Science in Sports & Exercise · 2019
Typearticle
Languageen
FieldEngineering
TopicOptical Coherence Tomography Applications
Canadian institutionsLakehead University
Fundersnot available
KeywordsOptical coherence tomographyMicrocirculationLaser Doppler velocimetrySpeckle patternBlood flowDecorrelationMedicineBiomedical engineeringNuclear medicineOphthalmologyCardiologyInternal medicineMathematicsOpticsPhysics

Abstract

fetched live from OpenAlex

INTRODUCTION: Optical coherence tomography (OCT) is a novel high-resolution imaging technique capable of visualizing in vivo structures at a resolution of ~10 μm. We have developed specialized OCT-based approaches that quantify diameter, speed, and flow rate in human cutaneous microvessels. In this study, we hypothesized that OCT-based microvascular assessments would possess comparable levels of reliability when compared with those derived using conventional laser Doppler flowmetry (LDF). METHODS: Speckle decorrelation images (OCT) and red blood cell flux (LDF) measures were collected from adjacent forearm skin locations on 2 d (48 h apart), at baseline, and after a 30-min rapid local heating protocol (30°C-44°C) in eight healthy young individuals. OCT postprocessing quantified cutaneous microvascular diameter, speed, flow rate, and density (vessel recruitment) within a region of interest, and data were compared between days. RESULTS: Forearm skin LDF (13 ± 4 to 182 ± 31 AU, P < 0.05) and OCT-derived diameter (41.8 ± 6.6 vs 64.5 ± 6.9 μm), speed (68.4 ± 9.5 vs 89.0 ± 7.3 μm·s), flow rate (145.0 ± 60.6 vs 485 ± 132 pL·s), and density (9.9% ± 4.9% vs 45.4% ± 5.9%) increased in response to local heating. The average OCT-derived microvascular flow response (pL·s) to heating (234% increase) was lower (P < 0.05) than the LDF-derived change (AU) (1360% increase). Pearson correlation was significant for between-day local heating responses in terms of OCT flow (r = 0.93, P < 0.01), but not LDF (P = 0.49). Bland-Altman analysis revealed that between-day baseline OCT-derived flow rates were less variable than LDF-derived flux. CONCLUSIONS: Our findings indicate that OCT, which directly visualizes human microvessels, not only allows microvascular quantification of diameter, speed, flow rate, and vessel recruitment but also provides outputs that are highly reproducible. OCT is a promising novel approach that enables a comprehensive assessment of cutaneous microvascular structure and function in humans.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.247
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueMedicine & Science in Sports & ExerciseSame topicOptical Coherence Tomography ApplicationsFrench-language works237,207