MétaCan
Menu
Back to cohort
Record W2918703441 · doi:10.1111/cid.12737

Quantitative in vitro comparison of the thrombogenicity of commercial dental implants

2019· article· en· W2918703441 on OpenAlexvenueno aff
Vincent Milleret, Philipp S. Lienemann, Sebastian Bauer, Martin Ehrbar

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2019
Typearticle
Languageen
FieldMedicine
TopicPeriodontal Regeneration and Treatments
Canadian institutionsnot available
Fundersnot available
KeywordsThrombogenicityOsseointegrationBiomedical engineeringDental implantSurface roughnessDentistryFibrinMaterials scienceCoagulationChemistryImplantPlateletMedicineSurgeryComposite materialInternal medicineImmunology

Abstract

fetched live from OpenAlex

BACKGROUND: Dental implants often have surface modifications that alter surface topography and chemistry to improve osseointegration and thereby increase treatment predictability. Surface contact-induced blood coagulation is associated with the onset of osseointegration. PURPOSE: To quantitatively evaluate the thrombogenicity of two commercially available dental implants that have similar surface roughness but different surface chemistry. MATERIAL AND METHODS: Two commercially available dental implants with anodized or sandblasted acid-etched surfaces were evaluated for thrombogenic properties. Thrombogenicity was assessed by incubating implants for 1 hour in fresh, partially heparinized blood followed by hemocyte quantification, microscopic evaluation, and quantification of thrombogenic biomarkers. RESULTS: Fibrin coverage was significantly higher on the anodized surface compared with the sandblasted acid-etched surface (P < 0.0001). Platelet and white blood cell attachment followed a similar pattern. The increased thrombogenicity was confirmed based on a significant increase in the levels of the coagulation cascade biomarkers, thrombin antithrombin complex, and β-thromboglobulin (all P < 0.05). CONCLUSION: Dental implants with comparable roughness but differing surface chemistry had differing extents of blood contact activation. These data suggest that surface chemistry from anodization augments implant thrombogenicity compared with that from sandblasting and acid-etching, which could have implications for osseointegration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.219
GPT teacher head0.536
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicPeriodontal Regeneration and TreatmentsFrench-language works237,207