MétaCan
Menu
Back to cohort
Record W2921575138 · doi:10.1097/ana.0000000000000592

High-fidelity Training Model for Measurement of Dynamic Optic Nerve Sheath Diameter Using Transorbital Ultrasonography

2019· article· en· W2921575138 on OpenAlexaff
Zakir Hajat, Michael Dinsmore, Lashmi Venkatraghavan

Bibliographic record

VenueJournal of Neurosurgical Anesthesiology · 2019
Typearticle
Languageen
FieldMedicine
TopicTraumatic Brain Injury and Neurovascular Disturbances
Canadian institutionsToronto Western HospitalUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsMedicineIntraclass correlationReproducibilityNuclear medicineCuffIntracranial pressureInterquartile rangeUltrasoundSurgeryRadiology

Abstract

fetched live from OpenAlex

BACKGROUND: Transorbital ultrasonographic measurement of optic nerve sheath diameter (ONSD) is an important technique for bedside assessment of raised intracranial pressure (ICP). However, developing competency for this clinical skill requires practice scans on both normal subjects and patients with raised ICP. The aim of this study is to develop a high-fidelity training model capable of measuring dynamic changes in ONSD and to test the reliability and reproducibility of the model at different simulated ICP values. MATERIALS AND METHODS: We designed and developed a high-fidelity training model for dynamic ONSD measurement using a hemispherical table tennis ball, mounted on a 3.0-mm pediatric microcuffed endotracheal tube (ETT). Two independent investigators then performed a randomized blinded study to assess the reliability and reproducibility of the model. A total of 30 ONSD measurements (10 measurements each for 3 ETT cuff volumes of 0.1, 0.2, and 0.3 mL, simulating an ONSD of a normal, borderline, and raised ICP, respectively) were performed by each investigator. Intraclass correlation coefficients and Bland-Altman plots were calculated to analyze the level of agreement between the investigators. RESULTS: Our model was able to provide dynamic changes in ONSD secondary to ETT cuff volume changes. Small increments of 0.1 mL cuff volume changes produced immediate changes in ONSD that are similar to those observed in patients. The median interobserver difference in ONSD was 0.3 mm (interquartile range, 0. to 0.4 mm). Intraclass correlation coefficient was 0.89, 0.89, and 0.90 for 0.1, 0.2, and 0.3 mL ETT cuff volumes, respectively. CONCLUSIONS: We have developed a clinically relevant model capable of simulating changes in ONSD in patients with normal and raised ICP. This model could be a valuable training tool to gain scanning experience in optic nerve ultrasonography, and improve operators' technical abilities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.889
Threshold uncertainty score0.605

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.067
GPT teacher head0.286
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Neurosurgical AnesthesiologySame topicTraumatic Brain Injury and Neurovascular DisturbancesFrench-language works237,207