MétaCan
Menu
Back to cohort
Record W2921806009 · doi:10.28920/dhm49.1.48-56

The performance of ‘temperature stick’ carbon dioxide absorbent monitors in diving rebreathers

2019· article· en· W2921806009 on OpenAlexaff
Mårten Silvanius, Simon J Mitchell, Neal W. Pollock, Oskar Frånberg, Mikael Gennser, Jerry Lindén, Peter Mesley

Bibliographic record

VenueDiving and Hyperbaric Medicine Journal · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiovascular and Diving-Related Complications
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsCarbon dioxideEnvironmental scienceEcologyBiology

Abstract

fetched live from OpenAlex

INTRODUCTION: Diving rebreathers use canisters containing soda lime to remove carbon dioxide (CO2) from expired gas. Soda lime has a finite ability to absorb CO₂. Temperature sticks monitor the exothermic reaction between CO₂ and soda lime to predict remaining absorptive capacity. The accuracy of these predictions was investigated in two rebreathers that utilise temperature sticks. METHODS: Inspiration and rEvo rebreathers filled with new soda lime were immersed in water at 19°C and operated on mechanical circuits whose ventilation and CO₂-addition parameters simulated dives involving either moderate exercise (6 MET) throughout (mod-ex), or 90 minutes of 6 MET exercise followed by 2 MET exercise (low-ex) until breakthrough (inspired PCO₂ [PiCO₂] = 1 kPa). Simulated dives were conducted at surface pressure (sea-level) (low-ex: Inspiration, n = 5; rEvo, n = 5; mod-ex: Inspiration, n = 7, rEvo, n = 5) and at 3-6 metres' sea water (msw) depth (mod-ex protocol only: Inspiration, n = 8; rEvo, n = 5). RESULTS: Operated at surface pressure, both rebreathers warned appropriately in four of five low-ex tests but failed to do so in the 12 mod-ex tests. At 3-6 msw depth, warnings preceded breakthrough in 11 of 13 mod-ex tests. The rEvo warned conservatively in all five tests (approximately 60 minutes prior). Inspiration warnings immediately preceded breakthrough in six of eight tests, but were marginally late in one test and 13 minutes late in another. CONCLUSION: When operated at even shallow depth, temperature sticks provided timely warning of significant CO₂ breakthrough in the scenarios examined. They are much less accurate during simulated exercise at surface pressure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.226
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueDiving and Hyperbaric Medicine JournalSame topicCardiovascular and Diving-Related ComplicationsFrench-language works237,207