Menu
Back to cohort
Record W2922166939 · doi:10.1063/1.5043393

Development and assessment of a multi-beam continuous-phantom-motion x-ray scatter projection imaging system

2019· article· en· W2922166939 on OpenAlexafffundabout
Christopher Dydula, George Belev, Paul C. Johns

Bibliographic record

VenueReview of Scientific Instruments · 2019
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of SaskatchewanCarleton University
FundersWestern Economic Diversification CanadaNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchNational Research Council CanadaCanada Foundation for InnovationUniversity of Saskatchewan
KeywordsImaging phantomCollimatorOpticsPhysicsData acquisitionDetectorPixelImage qualityPencil (optics)Projection (relational algebra)ScannerComputer scienceComputer visionImage (mathematics)

Abstract

fetched live from OpenAlex

X-ray image formation using scattered radiation can yield a superior contrast-to-noise ratio compared to conventional transmission x-ray imaging. A barrier to practical implementation of scatter imaging systems has been slow image acquisition. We have developed a projection imaging system which uses five monoenergetic pencil beams in combination with continuous phantom motion to achieve acquisition times that are practical for medical and security applications. The system was configured at the Canadian Light Source synchrotron and consists of a primary collimator, motorized stages for phantom translation, a flat-panel x-ray detector for measuring scattered x rays, and photodiodes for simultaneously measuring transmitted x rays. Image generation requires several corrections to raw data artifacts arising from the nature of the detector, x-ray source, and acquisition procedure. We developed a novel correction for pixel location inaccuracy arising from continuous phantom motion. A five-beam system had nearly five times faster acquisition than a single-beam system. Continuous motion acquisition was approximately 30 times faster than step-and-shoot acquisition. The total acquisition time for a 9 cm × 5 cm phantom with 8425 pixels was just over 2 min. Image quality was also assessed, in part to determine its relation to acquisition speed. The width of sharp material boundaries was found to be at a minimum equal to the pencil beam width (1.75 mm) and to have an additional width equal to the product of the phantom translation speed and the acquisition time per pixel (up to 1.0 mm in our experiments). Contrast-detail performance was independent of acquisition speed, depending only on phantom entrance x-ray fluence. Pixel signal-to-noise ratio measurements indicate that detector readout noise is important for the scatter data, even for phantom air kerma as high as 30 mGy. Images could be improved with a detector having lower readout noise and higher sensitivity. Its spatial resolution could be moderate. We confirmed that for the same range of λ−1 sin(θ/2), where λ is the x-ray wavelength and θ is the scattering angle, scatter images acquired using different beam energies (33–70 keV) had nearly identical contrast.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.818
Threshold uncertainty score0.570

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.269
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2019
Admission routes3
Has abstractyes

Explore more

Same venueReview of Scientific InstrumentsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207