MétaCan
Menu
Back to cohort
Record W2922974050 · doi:10.1159/000499092

The ex vivo and in vivo Characteristics of New DrillCut<sup>TM</sup> Prostate Morcellator after Holmium Laser Enucleation of the Prostate: A Pilot Study

2019· article· en· W2922974050 on OpenAlexaff
Amr Hodhod, Fabiola Oquendo, Hani H. Nour, Ryan Kelly, Walid Shahrour, Ahmed Kotb, Owen Prowse, Hazem Elmansy

Bibliographic record

VenueUrologia Internationalis · 2019
Typearticle
Languageen
FieldMedicine
TopicUrinary Bladder and Prostate Research
Canadian institutionsNOSM University
Fundersnot available
KeywordsMedicineEnucleationProstateEx vivoIn vivoAdenomaUrologyNuclear medicineSurgeryInternal medicineCancer

Abstract

fetched live from OpenAlex

INTRODUCTION: The DrillCutTM morcellator is marketed for its fast and highly efficient removal of prostatic tissue and a higher level of patient safety. However, a paucity of publications has looked into its actual efficacy and safety. The aim of our study was to evaluate its ex vivo and in vivo efficiency and to compare its results with other devices presented in the literature. PATIENTS AND METHODS: We conducted a prospective pilot study on patients who underwent holmium laser enucleation of the prostate (HoLEP) from 2017 to 2018 using the Top-Down technique. Enucleated adenomas were morcellated using the DrillCutTM morcellator. We collected both preoperative and operative data. Operative data included the enucleated adenoma weight and operative time. Various morcellator parameters were collected including morcellation time and efficiency. We recorded the encountered complications and device malfunction. Ex vivo characteristics were evaluated in terms of morcellation speed and aspiration power. RESULTS: Sixty consecutive patients with a median age of 72.8 years were included. The enucleated adenoma was retrieved in 12.5 min (4-58). The median resected prostatic weight was 90 g (44-242). The DrillCutTM efficiency was calculated as 6.46 g/min (2.7-15). Only one patient had a simple bladder mucosal injury. Device malfunction was encountered in 4 patients (6.6%) due to blockage of the morcellator blades. The ex vivo aspiration speed was 52 s/L, while the morcellation power was 14 g/2 min. CONCLUSION: Our results showed that the DrillCut morcellator was effective and safe in managing our patients post-HoLEP. The DrillCutTM has better ex vivo morcellation power but modest aspiration speed in comparison to other morcellators.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.266
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueUrologia InternationalisSame topicUrinary Bladder and Prostate ResearchFrench-language works237,207