MétaCan
Menu
Back to cohort
Record W2923754159 · doi:10.1647/2017-291

Comparison of a Point-of-care Cholesterol Meter With a Reference Laboratory Analyzer in Companion Psittaciformes

2019· article· en· W2923754159 on OpenAlexaff
Trinita Barboza, Hugues Beaufrère

Bibliographic record

VenueJournal of Avian Medicine and Surgery · 2019
Typearticle
Languageen
FieldImmunology and Microbiology
TopicBird parasitology and diseases
Canadian institutionsUniversity of Guelph
Fundersnot available
KeywordsSpectrum analyzerPoint of carePsittaciformesCoefficient of variationHematocritLimits of agreementMedicineBland–Altman plotReproducibilityAccuracy and precisionTotal cholesterolHemolysisCholesterolInternal medicineMathematicsStatisticsBiologyNuclear medicinePathologyComputer science

Abstract

fetched live from OpenAlex

Hypercholesterolemia is common in captive Psittaciformes. A point-of-care cholesterol analyzer would be useful to monitor hypercholesterolemia in psittacine birds. We compare a point-of-care cholesterol analyzer (PTS-Diagnostics CardioChek) with a reference laboratory analyzer (Roche Cobas c501) and provide initial assessment of precision and accuracy. A prospective method comparison study was designed to compare the CardioChek and Cobas c501 by assessment of clinical and analytical agreement using Passing-Bablock regression analysis and difference plots. Initial accuracy was assessed by running cholesterol standards, and initial precision was assessed by calculating between-run coefficient of variation on samples from selected birds. A total of 42 psittacine birds were sampled. No significant constant bias was found between the Cobas and CardioChek. However, a significant negative proportional bias was evident, suggesting that the point-of-care analyzer tended to underestimate cholesterol values. Lipemia and hemolysis had strong effects on increasing bias. Hematocrit, glucose level, and genus had no significant impact on bias, controlling for lipemia and hemolysis. Accuracy of the CardioCheck was suboptimal to that of the Cobas, but precision was good. When defining hypercholesterolemia as >8 mmol/L (309 mg/dL), the CardioChek had a sensitivity of 57% and specificity of 96%. There was neither analytical nor clinical agreement between the CardioChek and Cobas c501. Values obtained from the CardioChek cannot be used to determine or monitor hypercholesterolemia in parrots in the absence of analyzer-specific reference intervals.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.268

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.308
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Avian Medicine and SurgerySame topicBird parasitology and diseasesFrench-language works237,207