MétaCan
Menu
Back to cohort
Record W2931659196 · doi:10.1097/sga.0000000000000367

Evaluation of Noninvasive Thermometers in an Endoscopy Setting

2019· article· en· W2931659196 on OpenAlexaff
Stacie Blake, Kellie Fries, Lauren Higginbotham, Carol Lorei, Michael F. McGee, Robert J. Murray, Melissa Priest, J. Carrillo Rangel, Kara Remick-Erickson, Lise Schneider, Barbara Vodopest, Aline Moore

Bibliographic record

VenueGastroenterology Nursing · 2019
Typearticle
Languageen
FieldMedicine
TopicThermal Regulation in Medicine
Canadian institutionsRegistered Nurses' Association of Ontario
Fundersnot available
KeywordsThermometerMedicineLimits of agreementEndoscopyTemporal arteryNuclear medicineSurgeryInternal medicinePhysics

Abstract

fetched live from OpenAlex

The measurement of body temperature is an important aspect of assessment prior to invasive procedures. The purpose of the study was to determine the level of agreement between temporal artery, noncontact infrared, and disposable oral electronic thermometers to a clinical reference device (nondisposable oral electronic thermometer) in outpatients prior to an endoscopic procedure. A descriptive, method-comparison study design was used to compare 3 noninvasive thermometers with a clinical reference device. Four noninvasive temperatures were measured with 3 test devices (temporal artery with ear tap; temporal artery without ear tap; disposable oral electronic; and noncontact infrared), followed by measurement with the clinical reference device (nondisposable, oral electronic). Differences (bias) and limits of agreement (±1.96 SD) were calculated for the test devices and graphed using Bland-Altman method. Clinically acceptable levels of agreement were set at a bias of 0.54 °F or less and precision of 0.90 °F or less. A total of 25 endoscopy patients (N = 14 female; N = 11 male) were studied, with temperatures ranging from 97.5 to 98.9, averaging 98.1 ± 0.3 °F. All thermometers, with the exception of the noncontact infrared (0.66 °F), had acceptable ranges for use in clinical practices. Findings from this study support the use of both temporal artery and disposable oral electronic thermometers in afebrile outpatients but not the noncontact infrared thermometer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.232
Threshold uncertainty score0.370

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.340
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueGastroenterology NursingSame topicThermal Regulation in MedicineFrench-language works237,207