MétaCan
Menu
Back to cohort
Record W2934718566 · doi:10.1177/0309364619836353

Fabrication and application of an adjustable myoelectric transhumeral prosthetic socket

2019· article· en· W2934718566 on OpenAlexaff
Jonathon S. Schofield, Katherine R. Schoepp, Michael Stobbe, Paul D. Marasco, Jacqueline S. Hebert

Bibliographic record

VenueProsthetics and Orthotics International · 2019
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsGlenrose Rehabilitation HospitalUniversity of Alberta
FundersCommon FundNational Institutes of Health
KeywordsComputer scienceAbandonment (legal)Biomedical engineeringMedicine

Abstract

fetched live from OpenAlex

BACKGROUND AND AIM: Although upper limb myoelectric prostheses can offer improved functionality and dexterity over body-powered systems, abandonment rates remain high. User dissatisfaction in comfort and control are among the top contributors. The design of the prosthetic socket must be comfortable, while maintaining contact of control electrodes with the residual limb throughout the day. We present a myoelectric socket design that provides user-adjustable compression over electrode control sites to promote consistent control, while maintaining comfort and fit. TECHNIQUE: A cable tensioning system was threaded through a series of paneled windows in the socket wall over electrode sites. Adjusting tension provided tuning of electrode contact. DISCUSSION: A case study of a single transhumeral prosthetic user with a follow-up interview 11 months post delivery suggests that our adjustable design has the potential to address control and comfort challenges, critical factors in myoelectric prosthetic use, and abandonment. CLINICAL RELEVANCE: Achieving consistent electrode contact with muscle control sites in traditional rigid sockets is a critical challenge for myoelectric prostheses. We present a unique solution via user-adjustable electrode contacts built into the socket.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.205
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueProsthetics and Orthotics InternationalSame topicMuscle activation and electromyography studiesFrench-language works237,207