MétaCan
Menu
Back to cohort
Record W2935706637 · doi:10.3171/foc.2000.8.2.6

Localization of somatosensory function by using positron emission tomography scanning: a comparison with intraoperative cortical stimulation

2000· article· en· W2935706637 on OpenAlexaff
Richard G. Bittar, André Olivier, Abbas F. Sadikot, Frédérick Andermann, Roch M. Comeau, Martin Cyr, T.M. Peters, David C. Reutens

Bibliographic record

VenueNeurosurgical FOCUS · 2000
Typearticle
Languageen
FieldMedicine
TopicCerebrovascular and Carotid Artery Diseases
Canadian institutionsMcGill UniversityMontreal Neurological Institute and Hospital
Fundersnot available
KeywordsPositron emission tomographySomatosensory systemNuclear medicineStimulationMedicineSensory stimulation therapyNeurosciencePsychologyInternal medicine

Abstract

fetched live from OpenAlex

Object To investigate the utility of [ 15 O]H 2 O positron emission tomography (PET) activation studies in the presurgical mapping of primary somatosensory cortex, the authors compared the magnitude and location of activation foci obtained using PET scanning with the results of intraoperative cortical stimulation (ICS). Methods The authors used PET scanning and vibrotactile stimulation (of the face, hand, or foot) to localize the primary somatosensory cortex before surgical resection of mass lesions or epileptogenic foci affecting the central area in 20 patients. With the aid of image-guided surgical systems, the locations of significant activation foci on PET scanning were compared with those of positive ICS performed at craniotomy after the patient had received a local anesthetic agent. In addition, the relationship between the magnitude and statistical significance of blood flow changes and the presence of positive ICS was examined. In 22 (95.6%) of 23 statistically significant (p < 0.05) PET activation foci, spatially concordant sites on ICS were also observed. Intraoperative cortical stimulation was positive in 40% of the PET activation studies that did not result in statistically significant activation. In the patients showing these results, there was a clearly identifiable t-statistic peak that was spatially concordant with the site of positive ICS in the sensorimotor area. All PET activation foci with a t statistic greater than 4.75 were associated with spatially concordant sites of positive ICS. All PET activation foci with a t statistic less than 3.2 were associated with negative ICS. Conclusions Positron emission tomography is an accurate method for mapping the primary somatosensory cortex before surgery. The need for ICS, which requires local anesthesia, may be eliminated when PET foci with high (> 4.75) or low (< 3.20) t-statistic peaks are elicited by vibrotactile stimulation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.551
Threshold uncertainty score0.503

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.254
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueNeurosurgical FOCUSSame topicCerebrovascular and Carotid Artery DiseasesFrench-language works237,207