MétaCan
Menu
Back to cohort
Record W2936804657 · doi:10.1109/tnsre.2019.2910011

Hand Extension Robot Orthosis (HERO) Glove: Development and Testing With Stroke Survivors With Severe Hand Impairment

2019· article· en· W2936804657 on OpenAlex
Aaron Yurkewich, Debbie Hébert, Rosalie H. Wang, Alex Mihailidis

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueIEEE Transactions on Neural Systems and Rehabilitation Engineering · 2019
Typearticle
Languageen
FieldMedicine
TopicStroke Rehabilitation and Recovery
Canadian institutionsUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of TorontoToronto Rehabilitation InstituteAGE-WELL
KeywordsHEROPhysical medicine and rehabilitationStroke (engine)RobotExtension (predicate logic)MedicinePsychologyComputer scienceEngineeringArtificial intelligenceMechanical engineeringProgramming language

Abstract

fetched live from OpenAlex

The hand extension robot orthosis (HERO) glove was iteratively designed with occupational therapists and stroke survivors to enable stroke survivors with severe hand impairment to grasp and stabilize everyday objects, while being portable, lightweight, and easy to set up and use. The robot consists of a batting glove with artificial tendons embedded into the glove's fingers. The tendons are pulled and pushed by a linear actuator to extend and flex the fingers. The robot's finger extension and grasp assistance are automated using inertial measurement unit signal thresholds. Five stroke survivors (Chedoke McMaster Stroke Assessment - Stage of Hand 1-3) put on the HERO Glove in 1-3 minutes, with assistance. The stroke survivors performed significantly better on the Box and Block Test (2.8 more blocks transferred, ) while wearing the HERO Glove than when not wearing the glove. Four stroke survivors could only transfer blocks while wearing the HERO Glove. The HERO Glove enabled these stroke survivors to more fully extend their index finger (an increase of 97.5°, ) and three of five stroke survivors were better able grasp a water bottle. Therapists and stroke survivors suggested increasing the HERO Glove's grip force assistance and valued the glove's portability, lightweight design and potential usefulness in assisting with task-based therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.647
Threshold uncertainty score0.707

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.207
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it