MétaCan
Menu
Back to cohort
Record W2938735705 · doi:10.1097/bto.0000000000000371

Biomechanical Comparison of Pronator Quadratus Repair Techniques in the Modified Henry Approach for Distal Radius Fracture

2019· article· en· W2938735705 on OpenAlexaff
Andréanne Marmen, Josianne Lepine, Élisabeth Leblanc, Frédéric Balg

Bibliographic record

VenueTechniques in Orthopaedics · 2019
Typearticle
Languageen
FieldMedicine
TopicOrthopedic Surgery and Rehabilitation
Canadian institutionsUniversité de Sherbrooke
Fundersnot available
KeywordsMedicineCadaveric spasmFibrous jointCadaverWristFixation (population genetics)SurgeryDeep fasciaPopulation

Abstract

fetched live from OpenAlex

Background: Open reduction and volar plate fixation of distal radius fracture frequently involve detaching the pronator quadratus muscle. Repair maybe difficult due to friable muscle fascia or bulky plate. This study evaluates the strength of 3 repair techniques. Methods and Results: Repair with separate Simple Sutures, Continuous Suture, or Suture Anchors was tested on 3 groups of 6 cadaver forearms. A distraction load was applied to all repairs on a traction simulator until there was a failure of either the suture, the muscle or the anchor. Simple Suture group could resist 20.7 N, the Continuous Suture group 33.3 N, and the Suture Anchors group 42.5 N. The load to displacement were, respectively, 20.0, 25.9, and 34.6 N. The mode of failure was noted. Conclusions: This cadaveric study shows that if deemed necessary for soft tissue coverage or for biological aid in fracture healing, suture anchor is the strongest repair choice for pronator quadratus. This conclusion must be weighed against the fact that no in vivo tensile strength value sustained by the pronator quadratus is known in the literature and that simple suture could be sufficient to hold the repaired muscle while the wrist is immobilized postoperatively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.324
Teacher spread0.301 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueTechniques in OrthopaedicsSame topicOrthopedic Surgery and RehabilitationFrench-language works237,207