MétaCan
Menu
Back to cohort
Record W2944166457 · doi:10.1016/j.jmbbm.2019.05.002

Ultrastructural response of tendon to excessive level or duration of tensile load supports that collagen fibrils are mechanically continuous

2019· article· en· W2944166457 on OpenAlexafffund
K. Hijazi, Kathy L. Singfield, Samuel P. Veres

Bibliographic record

VenueJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2019
Typearticle
Languageen
FieldMedicine
TopicTendon Structure and Treatment
Canadian institutionsDalhousie UniversitySaint Mary's University
FundersNatural Sciences and Engineering Research Council of CanadaCanada Foundation for Innovation
KeywordsTendonFibrilSlippageCollagen fibrilUltimate tensile strengthMaterials scienceUltrastructureComposite materialAnatomyBiophysicsMedicineBiology

Abstract

fetched live from OpenAlex

The basic collagen fibril structure of tendons continues to be debated in the literature. Some studies have proposed that collagen fibrils are longitudinally discontinuous, with the load-bearing ability of tendon dependent on interfibrillar shear strength. Other evidence indicates that collagen fibrils are probably structurally continuous, running uninterrupted from osteotendinous to myotendinous junction. In this study we explored the question of collagen fibril continuity in tendon by examining fibril response to tendon loading. Tendons were subjected to high stress and/or long duration tensile loading routines, after which we examined the ultrastructure of the tendons using differential scanning calorimetry and scanning electron microscopy, comparing the results from the loaded tendons to control samples taken from the same tendons prior to loading. Our results show that under ramp loading, collagen fibril damage begins near the end of the linear region in the stress-strain response (i.e., near the yield point). When tendons are allowed to gradually elongate under static load, tendon rupture is caused by failure of collagen fibrils, not uncontrolled slippage between fibrils. Our findings indicate that the collagen fibrils of tendon are at least sufficiently long to be mechanically continuous, meaning that tensile failure of tendon does not occur as the result of uncontrolled slippage between fibrils, but by failure of the fibrils themselves.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.293
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsSame topicTendon Structure and TreatmentFrench-language works237,207