MétaCan
Menu
Back to cohort
Record W2945195048 · doi:10.1007/s00330-019-06234-4

High sensitivity and specificity of 4D-CTA in the detection of cranial arteriovenous shunts

2019· article· en· W2945195048 on OpenAlexaff
Matthijs in ‘t Veld, Rolf Fronczek, Marlise P. dos Santos, Marianne A.A. van Walderveen, Frederick J. A. Meijer, Peter W. A. Willems

Bibliographic record

VenueEuropean Radiology · 2019
Typearticle
Languageen
FieldMedicine
TopicVascular Malformations Diagnosis and Treatment
Canadian institutionsUniversity of OttawaOttawa Hospital
Fundersnot available
KeywordsMedicineNeuroradiologyRadiologyDigital subtraction angiographyArteriovenous malformationArteriovenous fistulaPredictive valueInterventional radiologyAngiographyNeurosurgeryCerebral angiographyIntracranial Arteriovenous MalformationsNeurologyInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: In a prospective cohort study, we evaluated the diagnostic accuracy of time-resolved CT angiography (4D-CTA) compared to digital subtraction angiography (DSA) for detecting cranial arteriovenous shunts. MATERIAL AND METHODS: Patients were enrolled if a DSA had been ordered querying either a dural arteriovenous fistula (dAVF) or a cerebral arteriovenous malformation (bAVM). After enrolment, both a DSA and a 4D-CTA were performed. Both studies were evaluated using a standardized form. If a dAVF or bAVM was found, its classification, angioarchitectural details, and treatment options were recorded. RESULTS: Ninety-eight patients were enrolled and 76 full datasets were acquired. DSA demonstrated a shunting lesion in 28 out of 76 cases (prevalence 37%). 4D-CTA demonstrated all but two of these lesions (sensitivity of 93%) and produced one false positive (specificity of 98%). These numbers yielded a positive predictive value (PPV) of 96% and a negative predictive value (NPV) of 96%. Significant doubt regarding the 4D-CTA diagnosis was reported in 6.6% of all cases and both false-negative 4D-CTA results were characterized by such doubt. CONCLUSIONS: 4D-CTA has very high sensitivity and specificity for the detection of intracranial arteriovenous shunts. Based on these results, 4D-CTA may replace DSA imaging as a first modality in the diagnostic workup in a large number of patients suspected of a cranial dAVF or bAVM, especially if there is no doubt regarding the 4D-CTA diagnosis. KEY POINTS: • 4D-CTA was shown to have a high diagnostic accuracy and is an appropriate, less invasive replacement for DSA as a diagnostic tool for cranial arteriovenous shunts in the majority of suspected cases. • Doubt regarding the 4D-CTA result should prompt additional DSA imaging, as it is associated with false negatives. • False-positive 4D-CTA results are rare, but do exist.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.016
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.210
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueEuropean RadiologySame topicVascular Malformations Diagnosis and TreatmentFrench-language works237,207