MétaCan
Menu
Back to cohort
Record W2946158128 · doi:10.3747/pdi.2018.00233

A Peritoneal Dialysis Access Quality Improvement Initiative: A Single-Center Experience

2019· article· en· W2946158128 on OpenAlexaffabout
Tamara Glavinovic, Mina Kashani, Muthana Al Sahlawi, Elizabeth Anderson, Megan Freeman, Niki Dacouris, Andrea Rathe-Skafel, Jason Y. Lee, Mónica Farcas, Andrew Common, Philip A. McFarlane, Jeffrey Perl

Bibliographic record

VenuePeritoneal Dialysis International · 2019
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsToronto General HospitalSt. Michael's Hospital
Fundersnot available
KeywordsMedicineCatheterPeritoneal dialysisDialysis catheterSurgery

Abstract

fetched live from OpenAlex

Background Little evidence exists regarding optimal peritoneal dialysis (PD) access insertion pathways, benchmarking for patency targets, and definitions of access dysfunction. Methods This quality improvement (QI) project evaluated patients with PD catheters inserted at a single center in Toronto, Canada, following: establishment of PD catheter insertion protocols, a PD access coordinator, PD access operator training, and outcomes reporting. We define primary vs secondary PD catheter dysfunction by presentation before/after initial home PD treatment. We report catheter dysfunction rates, interventions restoring PD catheter patency (interventional radiology [IR] vs advanced laparoscopic [AL]) (embedded vs non-embedded) between 2012 and 2017. Results A total of 297 first PD catheters were inserted between January 2012 and December 2017. Interventional radiology PD catheters ( n = 94) were placed in older patients with greater comorbidities and less prior abdominal surgery than AL-placed catheters. Indications for IR insertion included need for urgent dialysis given resource availability (36.2% [ n = 34]) and prohibitive surgical risk (26.6% [ n = 25]). Interventional radiology-inserted catheters had overall (primary and secondary) dysfunction rates of 17%. Non-embedded AL catheters had 16.1% overall dysfunction. Embedded AL-inserted PD catheters had a 24.6% overall dysfunction rate. Among all dysfunctional catheters, IR manipulation was successful in 31% ( n = 11), and surgical revision was necessary in all unsuccessful cases with either lysis of adhesions or omentopexy to establish patency. Conclusion Our PD catheter QI initiative involved tracking, outcome reporting, defining PD catheter dysfunction and PD access insertion pathway development, yielding important insights into opportunities for program improvement. Multicenter research initiatives are needed to further improve PD access dysfunction definitions and to establish the best benchmarks for these metrics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.431
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0010.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0160.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.098
GPT teacher head0.432
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2019
Admission routes2
Has abstractyes

Explore more

Same venuePeritoneal Dialysis InternationalSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207