MétaCan
Menu
Back to cohort
Record W2951088995 · doi:10.1016/j.ctro.2019.06.006

The radiation dose tolerance of the brachial plexus: A systematic review and meta-analysis

2019· review· en· W2951088995 on OpenAlexaff
Michael Yan, Weidong Kong, A Kerr, Michael Brundage

Bibliographic record

VenueClinical and Translational Radiation Oncology · 2019
Typereview
Languageen
FieldMedicine
TopicPeripheral Nerve Disorders
Canadian institutionsQueen's University
Fundersnot available
KeywordsMedicineBrachial plexusMeta-analysisRelative riskIncidence (geometry)Publication biasProspective cohort studyStudy heterogeneityCohort studyMeta-regressionConfidence intervalEffective dose (radiation)Nuclear medicineInternal medicineRadiologySurgery

Abstract

fetched live from OpenAlex

Purpose We performed a systematic review and meta-analysis of studies reporting the incidence of radiation induced brachial plexopathy (RIBP) and the associated radiotherapy doses to this structure. Methods Databases were queried without language restriction for cohort studies reporting RIBP incidence and associated brachial plexus dose maximum dose (bpDmax). Studies specifying RIBP relative risk (RR) effect size were selected for meta-analysis. RRs for RIBP from each study were converted to a regression coefficient (β) and standard error corresponding to a continuous representation of bpDmax. The adjusted β from individual studies were combined using a random effects model and weighted by inverse variance (1/SE 2 ). The trim and fill approach was used to assess publication bias. Results We identified 25 studies that included 37 unique patient cohorts eligible for analysis. Seventeen cohorts experienced an RIBP incidence ≤5%, of which 6 cohorts exceeded conventional plexus constraints of 60 Gy for bpDmax. Five of the 6 cohorts were simulated with 3D-CT techniques. Meta-analysis of eligible studies demonstrated a significant increase in RIBP risk for each Gy increase in bpDmax (RR, 1.11; 95% CI 1.07–1.15). Results remained significant after adjustment for publication bias and when sensitivity analysis was performed. Conclusions Our results suggest that current brachial plexus constraints of 60–66 Gy are safe. Meta-analysis provides a log-linear model to quantify the association of brachial plexus dose and RIBP risk, and thus inform the therapeutic ratio for dose escalation. Further prospective studies reporting dosimetric data can better refine this model and inform brachial plexus constraint guidelines.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.027
metaresearch head score (Gemma)0.064
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.980
Threshold uncertainty score0.145

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0270.064
Meta-epidemiology (narrow)0.0040.002
Meta-epidemiology (broad)0.0200.053
Bibliometrics0.0100.009
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0030.002
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.154
GPT teacher head0.469
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations53
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueClinical and Translational Radiation OncologySame topicPeripheral Nerve DisordersFrench-language works237,207